Version High Density Connection type Standard Reading field Side (105°) Scanner design Line scanner Focus Fixed focus Light source Visible red light MTBF 20,000 h Laser class 2 (DIN EN 60825-1) Aperture angle ≤ 50° Scanning frequency 400 Hz … 1,200 Hz Code resolution 0.15 mm … 0.5 mm Reading distance 55 mm … 200 mm 1) - 1) For details see reading field diagram.
-
Performance
Bar code types All current code types, Code 39, Code 128, Code 93, Codabar, GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode Print ratio 2:1 … 3:1 No. of codes per scan 1 … 3 No. of codes per reading interval 1 … 10 (auto-discriminating) No. of characters per reading interval 100 No. of multiple readings 1 … 99
-
Interfaces
Serial (RS-232, RS-422/-485) ✔ , AUX (only RS-232) Function Host, AUX Data transmission rate 300 Baud … 57,600 Baud, AUX: 9,600 baud Ethernet ✔ , optional via external connection module (CDM + CMF) CAN bus ✔ Function SICK CAN sensor network (Master/Slave, Multiplexer) Data transmission rate 20 kbit/s … 1 Mbit/s Protocol CANopen, CSN (SICK CAN Sensor Network) PROFIBUS DP ✔ , optional via external connection module (CDM + CMF) EtherCAT – DeviceNet ✔ , optional via external connection module (CDM + CMF) Switching inputs 2 (“Sensor 1”, “Sensor 2”) Switching outputs 2 (“Result 1”, “Result 2”) Reading pulse Reflector polling, Switching input “Sensor 1”, non-powered, serial interface Optical indicators 4 LEDs (function indicator) Acoustic indicators Beeper/buzzer (can be switched off, can be allocated as a result indication function)
-
Mechanics/electronics
Electrical connection 1 x 15-pin D-Sub HD male connector (0.9 m) Operating voltage 10 V DC … 30 V DC 1) Power consumption 3.5 W Housing Die-cast zinc, does not contain paint wetting impairment substances Housing color Light blue (RAL 5012) Enclosure rating IP 65 (DIN 40 050) Protection class III (VDE 0106, IEC 1010-1) Weight 320 g, with connecting cable Dimensions (L x W x H) 72 mm x 62.7 mm x 35.2 mm - 1) UL certified for use with a Class 2 mains supply unit (checked to UL 1310)
-
Ambient data
Electromagnetic compatibility (EMC) EN 61000-6-2 / EN 55011 Vibration resistance IEC 68-2-6 Test FC Shock resistance IEC 68-2-27 Test EA Ambient operating temperature 0 °C … +40 °C Storage temperature –20 °C … +70 °C Permissible relative humidity ± 90 %, Non-condensing Ambient light immunity 2,000 lx, on bar code Bar code print contrast (PCS) ≥ 60 %
-
General notes
Life cycle phase Discontinued