Measurement principle HDDM+ Application Outdoor Light source Infrared (850 nm) Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014) Aperture angle Horizontal 275° Vertical 7.5° (Over 4 scan layers) Scanning frequency 50 Hz, 4 x 12.5 Hz Angular resolution 0.25°
0.125°, interlaced
0.0625°, interlaced
Heating Self-heating Working range 0.2 m … 64 m Scanning range At 10% remission 16 m At 90% remission 30 m Spot size 10.4 mrad x 8.7 mrad Amount of evaluated echoes 3
-
Mechanics/electronics
Connection type M12 round connectors with swivel connector Supply voltage 10 V DC … 30 V DC Power consumption 37 W, typ. 13 W, Start-up phase max. 30 W for 1 s Housing AlSi12, optics cover: PC Housing color Gray (RAL 7042) Enclosure rating IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013)
IP67 (IEC 60529:1989+AMD1:1999+AMD2:2013)
Protection class III (IEC 61140:2016-11) Electrical safety IEC 61010-1:2010-06 Weight 1.2 kg Dimensions (L x W x H) 151.9 mm x 150 mm x 92.5 mm
-
Safety-related parameters
MTBF 50 years MTTFD > 100 years
-
Performance
Scan/frame rate 55,000 measurement point/s … 165,000 measurement point/s Response time 4 layers, typ. 20 ms 1)
1 layer, typ. 80 ms
Systematic error ± 60 mm Statistical error ≤ 30 mm Integrated application Field evaluation with flexible fields on 4 levels
Data output
Number of field sets Up to 128 fields (32 fields can be configured over 4 layers) Simultaneous evaluation cases Up to 16 evaluations Filter Fog filter
Particle filter
Average filter
Median filter
Ground reference evaluation
Edge filter
Echo filter
- 1) Depending on the selected filter settings and the object size.
-
Interfaces
Ethernet ✔ , TCP/IP, UDP/IP Function Host, OPC, NTP, Measured data output (distance, RSSI) Data transmission rate 10/100 MBit/s Digital inputs/outputs I/O (8 (Multiport)) Output data Contamination indication
IMU (secondary sensor data)
Optical indicators 2 LEDs Configuration software SOPAS ET
Web server (display)
-
Ambient data
Object remission 2 % … > 1,000 % (Reflector) Electromagnetic compatibility (EMC) EN 61000-6-2:2005
EN 61000-6-3:2007+A1:2011
Vibration resistance 10 Hz … 150 Hz, 5 g, 20 frequency cycles 1) Shock resistance 15 g, 11 ms, 6 single shocks/axis 2)
10 g, 16 ms, 1,000 continuous shocks/axis 2)
Ambient operating temperature –30 °C … +50 °C Storage temperature –40 °C … +75 °C Ambient light immunity 80 klx - 1) IEC 60068-2-6:2007.
- 2) IEC 60068-2-27:2008.
-
General notes
Note on use The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
-
Classifications
eCl@ss 5.0 27270990 eCl@ss 5.1.4 27270990 eCl@ss 6.0 27270913 eCl@ss 6.2 27270913 eCl@ss 7.0 27270913 eCl@ss 8.0 27270913 eCl@ss 8.1 27270913 eCl@ss 9.0 27270913 eCl@ss 10.0 27270913 eCl@ss 11.0 27270913 eCl@ss 12.0 27270913 ETIM 5.0 EC002550 ETIM 6.0 EC002550 ETIM 7.0 EC002550 ETIM 8.0 EC002550 UNSPSC 16.0901 41111615