Features
Functional principle Photoelectric retro-reflective sensor Actuator Pneumatic, valve on board Max. number of sensors Approx. 30 1)
Approx. 50 2)
Logical principle of operation Single accumulation Type of Release Single release, block (slug) release Dimensions (W x H x D) 50 mm x 125.3 mm x 48.9 mm Sensing range max. 250 mm … 1,500 mm Sensing range 250 mm … 1,500 mm 3) Focus 7° Type of light Visible red light Light source LED 4) Light spot size (distance) Ø 20 mm (500 mm) Angle of dispersion 7° Adjustment Potentiometer, 9 turns Special applications ZoneControl - 1) When powerd from the end of the IR daisy chain.
- 2) When powerd from center of the IR daisy chain.
- 3) On reflective tape REF-7610-K.
- 4) Average service life: 100,000 h at TU = +25 °C.
-
Mechanics/electronics
Supply voltage 19.2 V DC … 27.6 V DC 1) Ripple < 5 Vpp 2) Current consumption 20 mA 3) Switching output PNP Signal voltage PNP HIGH/LOW Approx. VS – 0.5 V / 0 V Output current Imax. ≤ 100 mA Response time 2 ms Switching frequency 250 Hz Connection type Male connector M12, 4-pin Connection type for daisy chain Cable with female connector, M12, 4-pin 2 m Circuit protection A 4)
C 5)
D 6)
Protection class III Weight 175 g Housing material Plastic, ABS Enclosure rating IP65 Shock and vibration resistance According to IEC 68 Ambient operating temperature –10 °C … +55 °C Ambient temperature, storage –40 °C … +75 °C UL File No. NRKH.E189383 & NRKH7.E189383 Medium for valves Compressed air or neutral gases filtered, non-lubricated or lubricated Design solenoid valve 3/2-way valve Mode of operation solenoid valve Air to Drive (NC) Connection type solenoid valve Compressed air 2 x 8 mm diameter, output line 4 mm diameter Coil ratings 24 V DC 2 W Air flow rate Approx. 20 Nl/min Ventilation capacity Approx. 100 Nl/min Operating pressure range 4 bar … 7 bar - 1) Limit values.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load and valve deenergized.
- 4) A = VS connections reverse-polarity protected.
- 5) C = interference suppression.
- 6) D = outputs overcurrent and short-circuit protected.
-
Safety-related parameters
MTTFD 1,374 years DCavg 0 % B10d 20,000,000 Switching cycles 1) - 1) Only for devices containing electro-mechanical components. In this case, the MTTFD value of the entire device must be calculated from the given B10D value, the number of switching cycles and the given MTTFD value.
-
Pneumatic
Coil ratings 24 V DC 2 W Medium for valves Compressed air or neutral gases filtered, non-lubricated or lubricated Design solenoid valve 3/2-way valve Connection type solenoid valve Compressed air 2 x 8 mm diameter, output line 4 mm diameter Air flow rate Approx. 20 Nl/min Ventilation capacity Approx. 100 Nl/min Operating pressure range 4 bar … 7 bar
-
Classifications
eCl@ss 5.0 27270902 eCl@ss 5.1.4 27270902 eCl@ss 6.0 27270902 eCl@ss 6.2 27270902 eCl@ss 7.0 27270902 eCl@ss 8.0 27270902 eCl@ss 8.1 27270902 eCl@ss 9.0 27270902 eCl@ss 10.0 27270902 eCl@ss 11.0 27270902 eCl@ss 12.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 ETIM 8.0 EC002717 UNSPSC 16.0901 39121528