Key Commercial Data
Orderkey | 2902021 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 74 (C-5-2019) |
GTIN | 4046356651998 |
Weight per Piece (excluding packing) | 120.000 g |
Custom tariff number | 85437090 |
Country of origin | DE (Germany) |
Ambient conditions
Ambient temperature (operation) | -40 °C … 70 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Permissible humidity (operation) | 5 % … 95 % (non-condensing) |
Degree of protection | IP20 (not assessed by UL) |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Input data
Number of inputs | 1 |
---|---|
Configurable/programmable | Yes |
Voltage input signal | -50 mV … 50 mV (via DIP switch) |
0 mV … 50 mV (via DIP switch) | |
-60 mV … 60 mV (via DIP switch) | |
0 mV … 60 mV (via DIP switch) | |
-75 mV … 75 mV (via DIP switch) | |
0 mV … 75 mV (via DIP switch) | |
-80 mV … 80 mV (via DIP switch) | |
0 mV … 80 mV (via DIP switch) | |
-100 mV … 100 mV (via DIP switch) | |
0 mV … 100 mV (via DIP switch) | |
-120 mV … 120 mV (via DIP switch) | |
0 mV … 120 mV (via DIP switch) | |
-150 mV … 150 mV (via DIP switch) | |
0 mV … 150 mV (via DIP switch) | |
-200 mV … 200 mV (via DIP switch) | |
0 mV … 200 mV (via DIP switch) | |
-240 mV … 240 mV (via DIP switch) | |
0 mV … 240 mV (via DIP switch) | |
-300 mV … 300 mV (via DIP switch) | |
0 mV … 300 mV (via DIP switch) | |
-500 mV … 500 mV (via DIP switch) | |
0 mV … 500 mV (via DIP switch) | |
-600 mV … 600 mV (via DIP switch) | |
0 mV … 600 mV (via DIP switch) | |
-750 mV … 750 mV (via DIP switch) | |
0 mV … 750 mV (via DIP switch) | |
-800 mV … 800 mV (via DIP switch) | |
0 mV … 800 mV (via DIP switch) | |
-1 V … 1 V (via DIP switch) | |
0 V … 1 V (via DIP switch) | |
-1.2 V … 1.2 V (via DIP switch) | |
0 V … 1.2 V (via DIP switch) | |
-1.5 V … 1.5 V (via DIP switch) | |
0 V … 1.5 V (via DIP switch) | |
-2 V … 2 V (via DIP switch) | |
0 V … 2 V (via DIP switch) | |
-2.4 V … 2.4 V (via DIP switch) | |
0 V … 2.4 V (via DIP switch) | |
-3 V … 3 V (via DIP switch) | |
0 V … 3 V (via DIP switch) | |
-5 V … 5 V (via DIP switch) | |
0 V … 5 V (via DIP switch) | |
-6 V … 6 V (via DIP switch) | |
0 V … 6 V (via DIP switch) | |
-7.5 V … 7.5 V (via DIP switch) | |
0 V … 7.5 V (via DIP switch) | |
-8 V … 8 V (via DIP switch) | |
0 V … 8 V (via DIP switch) | |
-10 V … 10 V (via DIP switch) | |
0 V … 10 V (via DIP switch) | |
-12 V … 12 V (via DIP switch) | |
0 V … 12 V (via DIP switch) | |
-15 V … 15 V (via DIP switch) | |
0 V … 15 V (via DIP switch) | |
-20 V … 20 V (via DIP switch) | |
0 V … 20 V (via DIP switch) | |
-24 V … 24 V (via DIP switch) | |
0 V … 24 V (via DIP switch) | |
-30 V … 30 V (via DIP switch) | |
0 V … 30 V (via DIP switch) | |
max. input voltage | 33 V |
Input resistance of voltage input | > 10 kΩ |
Output data
Number of outputs | 1 |
---|---|
Configurable/programmable | Yes |
Voltage output signal | 0 V … 5 V (via DIP switch) |
1 V … 5 V (via DIP switch) | |
-5 V … 5 V (via DIP switch) | |
0 V … 10 V (via DIP switch) | |
2 V … 10 V (via DIP switch) | |
-10 V … 10 V (via DIP switch) | |
Current output signal | 0 mA … 20 mA (via DIP switch) |
4 mA … 20 mA (via DIP switch) | |
Max. output current | 22 mA |
Short-circuit current | < 32 mA |
Load/output load voltage output | ≥ 10 kΩ |
Load/output load current output | ≤ 600 Ω (at 20 mA) |
Ripple | < 20 mVPP(at 600 Ω) |
< 20 mVPP(at 600 Ω) |
Power supply
Nominal supply voltage | 24 V DC |
---|---|
Supply voltage range | 9.6 V DC … 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
Typical current consumption | 25 mA (Current output, at 24 V DC incl. load) |
54 mA (Current output, at 12 V DC incl. load) | |
Power consumption | ≤ 800 mW (at IOUT= 20 mA, 9.6 V DC, 600 Ω load) |
Connection data
Connection method | Push-in connection |
---|---|
Stripping length | 10 mm |
Conductor cross section solid | 0.14 mm² … 2.5 mm² (with ferrule) |
0.14 mm² … 2.5 mm² (without ferrule) | |
Conductor cross section flexible | 0.14 mm² … 2.5 mm² |
Conductor cross section AWG | 24 … 12 (flexible) |
General
No. of channels | 1 |
---|---|
Maximum transmission error | ≤ 0.1 % (of final value) |
Maximum temperature coefficient | 0.01 %/K |
Limit frequency (3 dB) | 30 Hz (via DIP switch) |
5 kHz (via DIP switch) | |
Step response (10-90%) | < 8.5 ms (with 30 Hz filter) |
Protective circuit | Transient protection |
Electrical isolation | Reinforced insulation in accordance with IEC 61010-1 |
Overvoltage category | II |
Degree of pollution | 2 |
Rated insulation voltage | 300 V |
Test voltage, input/output/supply | 3 kV (50 Hz, 1 min.) |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Color | gray |
Housing material | PBT |
Mounting position | any |
Assembly instructions | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada | UL 508 Listed |
Class I, Div. 2, Groups A, B, C, D T6 | |
Class I, Zone 2, Group IIC T6 | |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 2 |
EMC data
Designation | Electromagnetic RF field |
---|---|
Standards/regulations | EN 61000-4-3 |
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Standards and Regulations
Electromagnetic compatibility | Conformance with EMC directive |
---|---|
Noise emission | EN 61000-6-4 |
Standards/regulations | EN 61000-4-2 |
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
EN 61000-4-4 | |
EN 61000-4-5 | |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Electrical isolation | Reinforced insulation in accordance with IEC 61010-1 |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada | UL 508 Listed |
Class I, Div. 2, Groups A, B, C, D T6 | |
Class I, Zone 2, Group IIC T6 |
Environmental Product Compliance
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |
Classifications
[email protected]
[email protected] 4.0 | 27210100 |
---|---|
[email protected] 4.1 | 27210100 |
[email protected] 5.0 | 27210100 |
[email protected] 5.1 | 27210100 |
[email protected] 6.0 | 27210100 |
[email protected] 7.0 | 27210120 |
[email protected] 8.0 | 27210120 |
[email protected] 9.0 | 27210120 |
Ambient conditions
Ambient temperature (operation) | -40 °C … 70 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Permissible humidity (operation) | 5 % … 95 % (non-condensing) |
Degree of protection | IP20 (not assessed by UL) |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |