Key Commercial Data
Orderkey | 2908699 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 27 (C-5-2019) |
GTIN | 4055626323169 |
Weight per Piece (excluding packing) | 340.000 g |
Custom tariff number | 85371098 |
Country of origin | DE (Germany) |
Ambient conditions
Ambient temperature (operation) | -25 °C … 70 °C (observe derating) |
---|---|
Ambient temperature (storage/transport) | -40 °C … 80 °C |
Maximum altitude | ≤ 2000 m |
Degree of protection | IP20 |
Device supply
Rated control circuit supply voltage US | 24 V DC |
---|---|
Control supply voltage range | 19.2 V DC … 30 V DC |
Rated control supply current IS | 60 mA |
Type of protection | Surge protection |
Reverse polarity protection |
Input data
Input name | Control input: right/left and enable input |
---|---|
Note | The enable input is compatible with signals with blanking (semiconductor output signals with test pulse with max. 3 ms duration), unblanking pulses of max. 4 ms are tolerated without adversely affecting the safety function. |
Rated actuating voltage UC | 24 V DC |
Triggering voltage range | 19.2 V DC … 30 V DC |
Rated actuating current IC | 7 mA |
Switching threshold | 9.6 V (“0” signal) |
19.2 V (“1” signal) | |
Switching level | < 5 V DC (For EMERGENCY STOP) |
Typical turn-off time | < 30 ms |
Type of protection | Reverse polarity protection |
Output data load output
Output name | AC output |
---|---|
Rated operating voltage Ue | 500 V AC |
Operating voltage range | 42 V AC … 550 V AC |
Rated operating current Ie | 3 A (AC-51) |
3 A (AC-53a) | |
Mains frequency | 50/60 Hz |
Load current range | 180 mA … 3 A |
Trigger characteristic in acc. with IEC 60947-4-2 | Class 10 |
Cooling time | 20 min. (for auto reset) |
Leakage current | 0 mA |
Output data reply output
Output name | Acknowledge output |
---|---|
Note | Confirmation: floating change-over contact, signal contact |
Contact type | 1 PDT |
Switching capacity according to IEC 60947-5-1 | 2 A (24 V, DC13) |
General
Switching frequency | ≤ 2 Hz (Load-dependent) |
---|---|
Mounting position | vertical (horizontal DIN rail, motor output below) |
Mounting type | DIN rail mounting |
Assembly instructions | alignable, for spacing see derating |
Operating mode | 100% operating factor |
Maximum power dissipation | 4.1 W |
Minimum power dissipation | 0.88 W |
Operating voltage display | Green LED |
Status display | Yellow LED |
Indication | Red LED |
Connection data
Connection name | Control circuits |
---|---|
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.2 mm² … 2.5 mm² |
Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
Conductor cross section AWG | 24 … 14 |
Torque | 0.5 Nm … 0.6 Nm |
5 lbf-in. … 7 lbf-in. |
Connection data 2
Connection name | Load circuit |
---|---|
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.2 mm² … 2.5 mm² |
Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
Conductor cross section AWG | 24 … 14 |
Torque | 0.5 Nm … 0.6 Nm |
5 lbf-in. … 7 lbf-in. |
Insulation characteristics
Rated insulation voltage | 550 V |
---|---|
Rated surge voltage | 6 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Designation | Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit |
Insulation | Safe isolation (IEC 60947-1) |
Designation | Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
Insulation | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
Standards and Regulations
Designation | Standards/regulations |
---|---|
Standards/regulations | EN 60947-1 |
EN 60947-4-2 | |
EN ISO 13849 | |
IEC 62061 | |
IEC 61508 |
Conformance/approvals
Designation | UL approval |
---|---|
Certificate | NLDX.E228652 |
NRNT.E172140 | |
Designation | Safety Integrity Level (SIL, IEC 61508) |
Identification | ≤ 3 |
Additional text | Safe shutdown |
Designation | Safety Integrity Level (SIL, IEC 61508) |
Identification | 2 |
Additional text | Motor protection |
Designation | Performance Level (ISO 13849) |
Identification | ≤ e |
Additional text | Safe shutdown |
Designation | Category (ISO 13849) |
Identification | ≤ 3 |
Additional text | Safe shutdown |
UL data
SCCR | 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
---|---|
5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) | |
FLA | 3 A (480 V AC) |
Group installation | 20 A (class RK5, SCCR 5kA (480 V AC), #24 – 14 AWG max. solid and stranded) |
30 A (class CC or J, SCCR 100kA (480 V AC), #24 – 14 AWG max, solid and stranded) | |
Category code | NLDX / NRNT |
Horsepower ratings | 0.5 hp (120 V AC / 208 V AC) |
1.5 hp (277 V AC / 480 V AC) | |
Ambient temperature (operation) | -25 °C … 55 °C |
Environmental Product Compliance
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |
Classifications
[email protected]
[email protected] 4.0 | 27021100 |
---|---|
[email protected] 4.1 | 27021100 |
[email protected] 5.0 | 27024000 |
[email protected] 5.1 | 27024000 |
[email protected] 6.0 | 27024000 |
[email protected] 7.0 | 27024002 |
[email protected] 8.0 | 27024002 |
[email protected] 9.0 | 27370905 |
ETIM
ETIM 2.0 | EC001037 |
---|---|
ETIM 3.0 | EC001037 |
ETIM 4.0 | EC001037 |
ETIM 5.0 | EC001037 |
ETIM 6.0 | EC001037 |
ETIM 7.0 | EC001037 |