Key Commercial Data
Orderkey | 2907877 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 50 (C-4-2017) |
GTIN | 4055626245027 |
Weight per Piece (excluding packing) | 49.600 g |
Custom tariff number | 85363030 |
Country of origin | DE (Germany) |
Ambient conditions
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -40 °C … 80 °C |
Ambient temperature (storage/transport) | -40 °C … 80 °C |
Altitude | ≤ 6000 m (amsl (above mean sea level)) |
Permissible humidity (operation) | 5 % … 95 % |
Shock (operation) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (operation) | 5g (10 … 500 Hz / 2.5 h / X, Y, Z) |
General
IEC test classification | II |
---|---|
T2 | |
EN type | T2 |
IEC power supply system | DC |
Mode of protection | (DC+) – (DC-) |
(DC+/DC-) – PE | |
Mounting type | on base element |
Color | light grey RAL 7035 |
Housing material | PA 6.6-FR 20% GF |
PBT-FR | |
Degree of pollution | 2 |
Flammability rating according to UL 94 | V-0 |
Type | Male |
Number of positions | 1 |
Surge protection fault message | optical |
Protective circuit
Nominal voltage UN | 48 V DC … 60 V DC |
---|---|
Maximum continuous voltage UC | 75 V DC |
Residual current IPE | ≤ 50 µA DC |
Nominal discharge current In(8/20) µs | 20 kA |
Maximum discharge current Imax(8/20) µs | 40 kA |
Impulse discharge current (10/350) µs, charge | 2 As |
Impulse discharge current (10/350) µs, specific energy | 4 kJ/Ω |
Impulse discharge current (10/350) µs, peak value limp | 4 kA |
Short-circuit current rating ISCCR | 0.2 kA (without backup fuse) |
6 kA (for 20 A gG/B backup fuse) | |
Voltage protection level Up | ≤ 0.5 kV |
Residual voltage Ures | ≤ 0.5 kV (at In) |
≤ 0.4 kV (at 10 kA) | |
≤ 0.35 kV (at 5 kA) | |
≤ 0.3 kV (at 2 kA) | |
TOV behavior at UT | 87 V DC (5 s / withstand mode) |
Response time tA | ≤ 25 ns |
Max. backup fuse with V-type through wiring | 20 A (gG / B at ISCCR> 200 A) |
Max. backup fuse with branch wiring | 20 A (gG / B at ISCCR> 200 A) |