Key Commercial Data
Orderkey | 1078433 |
---|---|
Packing unit | 1 |
Catalog page | Page 76 (C-4-2019) |
GTIN | 4055626793344 |
Custom tariff number | 85354000 |
Ambient conditions
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -40 °C … 80 °C |
Ambient temperature (storage/transport) | -40 °C … 80 °C |
Altitude | ≤ 2000 m (amsl (above mean sea level)) |
Permissible humidity (operation) | 5 % … 95 % |
Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (operation) | 5g (5 … 500 Hz / 2.5 h / X, Y, Z) |
General
IEC test classification | II / III |
---|---|
EN type | T2 / T3 |
IEC power supply system | TN-S |
TT | |
SPD failure behavior | OCM |
Accessibility | Accessible |
Installation location of the disconnect device | Internal |
Mode of protection | L-N |
L-PE | |
N-PE | |
Mounting type | 4 mm screw |
Color | light grey RAL 7035 |
Housing material | PA 6.6 |
Degree of pollution | 2 |
Distance between live and grounded parts | 3 mm |
Flammability rating according to UL 94 | V-0 |
Protection class | I |
Protective circuit
Nominal voltage UN | 100 V AC … 230 V AC (TN-S) |
---|---|
100 V AC … 230 V AC (TT) | |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous operating voltage UC(L-N) | 305 V AC |
Maximum continuous operating voltage UC(L-PE) | 265 V AC |
Maximum continuous voltage UC(N-PE) | 265 V AC |
Rated load current IL | 16 A |
Residual current IPE | ≤ 5 µA |
Nominal discharge current In(8/20) µs (L-N) | 5 kA |
Nominal discharge current In(8/20) µs (L-PE) | 5 kA |
Nominal discharge current In(8/20) µs (N-PE) | 10 kA |
Maximum discharge current Imax(8/20) µs (L-N) | 10 kA |
Maximum discharge current Imax(8/20) µs (L-PE) | 10 kA |
Maximum discharge current Imax(8/20) µs (N-PE) | 20 kA |
Combination wave UOC(L-N) | 10 kV |
Combination wave UOC(L-PE) | 10 kV |
Combination wave UOC(N-PE) | 20 kV |
Total discharge current Itotal(8/20) µs | 20 kA |
Follow current interrupt rating Ifi(N-PE) | 100 A () |
Short-circuit current rating ISCCR | 10 kA (6 A gG backup fuse) |
3 kA (16 A MCB B/C backup fuse) | |
Voltage protection level Up(L-N) | ≤ 1.3 kV |
Voltage protection level Up(L-PE) | ≤ 1.5 kV |
Voltage protection level Up(N-PE) | ≤ 1.5 kV |
TOV behavior at UT(L-N) | 336 V AC (5 s / withstand mode) |
440 V AC (120 min / safe failure mode) | |
TOV behavior at UT(L-PE) | 440 V AC (5 s / withstand mode) |
440 V AC (120 min / safe failure mode) | |
TOV behavior at UT(N-PE) | 1200 V AC (200 ms / safe failure mode) |
Response time tA(L-N) | ≤ 25 ns |
Response time tA(L-PE) | ≤ 100 ns |
Response time tA(N-PE) | ≤ 100 ns |
Max. backup fuse with V-type through wiring | 16 A (MCB B/C) |
Max. backup fuse with branch wiring | 16 A (MCB B/C) |
Connection data
Connection method | Screw terminal blocks |
---|---|
Screw thread | M3 |
Tightening torque | 0.6 Nm |
Stripping length | 8 mm |
2 conductors with same cross section, stranded min. | 0.2 mm² |
2 conductors with same cross section, stranded max. | 1.5 mm² |
Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
2 conductors with same cross section, solid min. | 0.2 mm² |
2 conductors with same cross section, solid max. | 1.5 mm² |
Conductor cross section solid | 0.2 mm² … 4 mm² |
Classifications
Ambient conditions
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -40 °C … 80 °C |
Ambient temperature (storage/transport) | -40 °C … 80 °C |
Altitude | ≤ 2000 m (amsl (above mean sea level)) |
Permissible humidity (operation) | 5 % … 95 % |
Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (operation) | 5g (5 … 500 Hz / 2.5 h / X, Y, Z) |