Key Commercial Data
| Orderkey | 1038568 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 403 (C-6-2019) |
| GTIN | 4055626592411 |
| Weight per Piece (excluding packing) | 0.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C … 70 °C (SMS mode only, note the derating information in the technical documentation for data connection) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C … 85 °C |
| Permissible humidity (operation) | 0 % … 95 % |
| Altitude | 2000 m |
| Degree of protection | IP20 |
General
| Electromagnetic compatibility | Conformance with RED Directive 2014/53/EU |
|---|---|
| Net weight | 231.8 g |
| Housing material | Polycarbonate |
| MTTF | 772 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| 363 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
| 150 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
| Wireless licences | Europe |
Power supply
| Supply voltage range | 93 V AC … 250 V AC (47.5 Hz … 63 Hz) |
|---|---|
| Max. current consumption | 90 mA |
| Typical current consumption | 15 mA (for 230 V AC) |
| Conductor cross section flexible max. | 2.50 mm² |
| Conductor cross section flexible min. | 0.20 mm² |
| Conductor cross section solid max. | 2.50 mm² |
| Conductor cross section solid min. | 0.20 mm² |
| Max. AWG conductor cross section, flexible | 14 |
| Min. AWG conductor cross section, flexible | 24 |
| Conductor cross section AWG max. | 14 |
| Conductor cross section AWG min. | 24 |
Serial interface
| Interface 1 | USB 2.0 |
|---|---|
| Connection method | Mini-USB type B, 5-pos. |
| Transmission length | ≤ 3 m (only for configuration and diagnostics) |
Wireless interface
| Interface description | GSM / GPRS / EDGE / LTE (FDD) |
|---|---|
| Frequency | 850 MHz (2 W (EGSM)) |
| 900 MHz (2 W (EGSM)) | |
| 1800 MHz (1 W (EGSM)) | |
| 1900 MHz (1 W (EGSM)) | |
| 800 MHz (LTE B20) | |
| 1800 MHz (LTE B3) | |
| 2600 MHz (LTE B7) | |
| GPRS | Multislot Class 33 |
| EDGE | Multislot Class 33 |
| LTE | CAT1 |
| Country support | Europe |
Digital outputs
| Output name | Relay output |
|---|---|
| Number of outputs | 4 |
| Contact type | N/O contact |
| Minimum switching voltage | 5 V |
| Maximum switching voltage | 125 V DC |
| 250 V AC | |
| Limiting continuous current | 5 A |
| Switching capacity | 750 VA |
| Electrical service life | 150000 cycles (5 A / 30 V DC) |
| 150000 cycles (3 A / 120 V AC) | |
| 30000 cycles (5 A / 250 V AC) |
Digital inputs
| Description of the input | Digital input |
|---|---|
| Number of inputs | 4 |
| Switching level “0” signal | 0 V AC … 50 V AC |
| Switching level “1” signal | 90 V AC … 250 V AC |
Standards and Regulations
| Electromagnetic compatibility | Conformance with RED Directive 2014/53/EU |
|---|---|
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | ± 6 kV |
| Indirect discharge | ± 6 kV |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 26 MHz … 6 GHz |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Standards/regulations | EN 61000-4-5 |
| Signal | ± 1 kV (Data line, asymmetrical) |
| Standards/regulations | EN 61000-4-6 |
| Frequency range | 0.15 MHz … 80 MHz |
| Standards/regulations | EN 61000-4-11 |
| EN 50360 | |
| EN 50121-4 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |
Classifications
[email protected]
| [email protected] 4.0 | 27250312 |
|---|---|
| [email protected] 4.1 | 27250312 |
| [email protected] 5.0 | 27242208 |
| [email protected] 5.1 | 27242200 |
| [email protected] 6.0 | 19179200 |
| [email protected] 7.0 | 19179290 |
| [email protected] 8.0 | 19179290 |
| [email protected] 9.0 | 27242608 |
Ambient conditions
| Ambient temperature (operation) | -25 °C … 70 °C (SMS mode only, note the derating information in the technical documentation for data connection) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C … 85 °C |
| Permissible humidity (operation) | 0 % … 95 % |
| Altitude | 2000 m |
| Degree of protection | IP20 |