Key Commercial Data
| Orderkey | 1015533 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 227 (C-6-2019) |
| GTIN | 4055626496740 |
| Weight per Piece (excluding packing) | 240.000 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer’s declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -35 °C … 60 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C … 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
| Designation | A1/A2 |
|---|---|
| Rated control circuit supply voltage US | 24 V DC -20 % / +25 % |
| Rated control supply current IS | typ. 80 mA |
| Power consumption at US | typ. 1.92 W |
| Inrush current | typ. 28 A (Δt = 30 µs at Us) |
| Filter time | 10 ms (For the logic. At A1 in the event of voltage dips at Us) |
| Protective circuit | Serial protection against polarity reversal Suppressor diode |
Digital inputs
| Input name | Sensor circuit |
|---|---|
| S12, S22 | |
| Description of the input | safety-related sensor inputs |
| NPN | |
| Number of inputs | 2 |
| Input voltage range “0” signal | 0 V DC … 5 V DC |
| Input voltage range “1” signal | 11 V DC … 30 V DC |
| Input current range “0” signal | 0 mA … 2 mA |
| Inrush current | < 11 mA (typically with US) |
| Current consumption | < 4.5 mA (typically with US) |
| Filter time | max. 3 ms (Test pulse width of low test pulses) |
| min. 21 ms (Test pulse rate for low test pulse) | |
| Max. permissible overall conductor resistance | 150 Ω |
| Concurrence input 1/2 | ∞ |
| Limit frequency | min. 0 Hz |
| max. 1 Hz | |
| Protective circuit/component | Varistor |
| Input name | Start circuit |
| S34 | |
| Description of the input | non-safety-related |
| NPN | |
| Number of inputs | 1 |
| Input voltage range “0” signal | 0 V DC … 5 V DC |
| Input voltage range “1” signal | 11 V DC … 30 V DC |
| Input current range “0” signal | 0 mA … 2 mA |
| Inrush current | < 8.6 mA (typically with US) |
| Current consumption | < 3.2 mA (typically with US) |
| Filter time | max. 3 ms (Test pulse width of low test pulses) |
| min. 21 ms (Test pulse rate for low test pulse) | |
| Max. permissible overall conductor resistance | 150 Ω |
| Limit frequency | min. 0 Hz |
| max. 1 Hz | |
| Protective circuit/component | Varistor |
Relay outputs: enabling current path
| Output name | Enabling current paths |
|---|---|
| 13/14, 23/24/34, 47/48/58 | |
| Output description | 2 N/O contacts each in series, safety-related, floating |
| Number of outputs | 3 (undelayed: 13/14, 23/24/34) |
| 2 (delayed: 47/48/58) | |
| Contact type | 5 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 12 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Limiting continuous current | 6 A |
| Inrush current | min. 3 mA |
| max. 6 A | |
| Sq. Total current | 108 A2(observe derating) |
| Switching capacity | min. 60 mW |
| Switching frequency | 0.5 Hz (depending on the set delay time) |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 4 A (24 V (DC13)) |
| 5 A (250 V (AC15)) | |
| Output fuse | 6 A gL/gG |
| 4 A gL/gG (for low-demand applications) |
Alarm outputs
| Designation | M1 |
|---|---|
| Output description | PNP |
| non-safety-related | |
| Number of outputs | 1 |
| Voltage | approx. 23 V DC (US– 1 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 10 ms at Us) |
| Protective circuit/component | Suppressor diode |
| Short-circuit protection | Yes |
Clock outputs
| Designation | S11, S21 |
|---|---|
| Output description | PNP |
| non-safety-related | |
| Number of outputs | 2 |
| Voltage | corresponds to US |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 10 ms at Us) |
| Cable length | max. 150 m |
| Protective circuit/component | Suppressor diode |
| Short-circuit protection | Yes |
Times
| Typical pickup time at US | 500 ms (with Uswhen controlled via A1) |
|---|---|
| Typical response time at US | < 40 ms (automatic start) |
| < 30 ms (manual, monitored start) | |
| Typical release time at US | < 25 ms (when controlled via S12 and S22 (only for undelayed contacts)) |
| < 5 ms (when controlled via A1; applicative deactivation via A1/A2 is not permitted) | |
| Delay time range | 0.2 s … 300 s ±5 % (can be set for 47/48/58) |
| Restart time | < 1 s (Boot time) |
| Recovery time | 500 ms (following demand of the safety function) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 155.43 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
| Status display | 5 x bi-color LED |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Torque | 0.5 Nm … 0.6 Nm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| 1 | |
| Designation | IEC 61508 – High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 – Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (4 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Category | 4 |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
| Safe isolation, reinforced insulation 6 kV between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14) and enabling current path (23/24/34) and enabling current path (47/48/58) | |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 10g (operation), 15g (transport) |
| Vibration (operation) | 10 Hz … 150 Hz, 2g |
| Conformance | CE-compliant |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |