Key Commercial Data
| Orderkey | 2981538 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 275 (C-6-2017) |
| GTIN | 4017918996826 |
| Weight per Piece (excluding packing) | 365.000 g |
| Custom tariff number | 90328900 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer’s declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C … 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C … 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | max. 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | |
|---|---|
| Nominal input voltage UN | 24 V DC |
| Input voltage range in reference to UN | 0.85 … 1.1 |
| Typical input current at UN | 100 mA |
| Voltage at input/start and feedback circuit | approx. 24 V DC |
| Typical response time | 15 ms |
| Typical release time | 12 ms |
| Recovery time | 1 s |
| Status display | Green LED |
| Protective circuit | Surge protection Suppressor diode |
| Limit frequency | 2 kHz (IN1, IN2) |
| 400 kHz (RJ45) |
Output data
| Contact type | 4 enabling current paths |
|---|---|
| Contact material | AgNi10, + 5 µm Au |
| Maximum switching voltage | 250 V AC/DC (when the gold layer is destroyed) |
| 60 V AC/DC (With gold layer existing) | |
| Minimum switching voltage | 100 mV AC/DC |
| Limiting continuous current | 5 A |
| 100 mA (alarm outputs) | |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 1 mA |
| Sq. Total current | 42.25 A2(ITH2= I12+ I22+ I32+ I42) |
| Interrupting rating (ohmic load) max. | 67 W (24 V DC, τ = 0 ms) |
| 36 W (48 V DC, τ = 0 ms) | |
| 43 MW (110 V DC, τ = 0 ms) | |
| 68 MW (220 V DC, τ = 0 ms) | |
| Switching capacity min. | 1 mW |
| Mechanical service life | > 50x 106cycles |
| Output fuse | 6 A gL |