Key Commercial Data
Orderkey | 1015503 |
---|---|
Packing unit | 1 |
GTIN | 4055626496467 |
Custom tariff number | 85371098 |
Note
Utilization restriction | EMC: class A product, see manufacturer’s declaration in the download area |
---|
Ambient conditions
Ambient temperature (operation) | -40 °C … 70 °C (observe derating) |
---|---|
Ambient temperature (storage/transport) | -40 °C … 70 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
Designation | A1/A2 |
---|---|
Rated control circuit supply voltage US | 24 V DC -20 % / +25 % (provide external protection) |
Rated control supply current IS | typ. 54 mA (No load) |
Power consumption at US | typ. 1.3 W |
Inrush current | < 5 A (Δt = 200 µs at Us) |
Filter time | 1 ms (For the logic. At A1 in the event of voltage dips at Us) |
Protective circuit | Parallel protection against polarity reversal Suppressor diode Provide external protection, see safety notes. Fuse type: 5 A FF |
Digital inputs
Input name | Sensor circuit |
---|---|
S10, S12, S22 | |
Description of the input | safety-related sensor inputs |
NPN, IEC 61131-2 type 3 (S10, S12) PNP (S22) |
|
Number of inputs | 3 |
Input voltage range “0” signal | 0 V DC … 5 V DC (S10, S12) |
S22 open | |
Input voltage range “1” signal | 11 V DC … 30 V DC (S10, S12) |
0 V … 0 V (S22) | |
Input current range “0” signal | 0 mA … 2 mA (S10, S12) |
Inrush current | < 10 mA (Typically with USat S10/S12, Δt = 500 µs) |
> -5 mA (typ. with USat S22, Δt = 500 µs) | |
Current consumption | 4 mA (S10, S12) |
-4 mA (S22) | |
Filter time | max. 1.5 ms (Test pulse width of low test pulses) |
Test pulse rate = 5 x Test pulse width | |
Does not apply for S22 | |
Deactivate switch-on pulses/light tests for safety applications. | |
Max. permissible overall conductor resistance | 150 Ω |
Concurrence input 1/2 | ∞ |
Protective circuit/component | Suppressor diode |
Input name | Start circuit |
S34, S35 | |
Description of the input | non-safety-related |
NPN | |
Number of inputs | 2 |
Input voltage range “1” signal | 19.2 V DC … 30 V DC |
Inrush current | < 10 mA (Typically with US, Δt |
Current consumption | < 7 mA (Typically with USat S34) |
< 5 mA (Typically with USat S35) | |
Max. permissible overall conductor resistance | 150 Ω |
Protective circuit/component | Suppressor diode |
Input name | External release |
S36 | |
Description of the input | safety-related |
NPN, IEC 61131-2, type 3 | |
Number of inputs | 1 |
Input voltage range “0” signal | 0 V DC … 5 V DC |
Input voltage range “1” signal | 11 V DC … 30 V DC |
Current consumption | 7 mA |
Protective circuit/component | Suppressor diode |
Digital outputs
Output name | 14, 24 |
---|---|
Output description | Safety-related digital outputs |
PNP, IEC 61131-2 Type 2 | |
Number of outputs | 2 |
Output voltage | ≥ 23 V DC (Us– 1 V) |
Output current | max. 2.4 A |
Inrush current | max. 4.8 A (Δt = 10 ms) |
Output voltage when switched off | < 5 V DC (in the safe state) |
Leakage current | max. 1 mA (in the safe state) |
Ohmic load | min. 12 Ω |
Max. capacitive load | max. 10 µF (2.4 A load) |
max. 4.7 µF (1 A load) | |
Max. inductive load | max. 1 H |
Min. load current | 2 mA |
Switching frequency | 1 Hz (Resistive, inductive, capacitive) |
Type of protection | Freewheeling circuit for inductive loads |
Limitation of the voltage induced on circuit interruption | max. 50 V |
Alarm outputs
Designation | M1 |
---|---|
Output description | PNP |
non-safety-related | |
Number of outputs | 1 |
Voltage | approx. 22 V DC (Us– 2 V) |
Current | max. 100 mA |
Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
Protective circuit/component | Suppressor diode |
Short-circuit protection | Yes |
Times
Typical pickup time at US | < 200 ms (with Uswhen controlled via A1) |
---|---|
Typical response time at US | < 200 ms (automatic start) |
< 175 ms (manual, monitored start) | |
Response time | < 10 ms (Take the extension of the response time into consideration if you switch several devices in sequence.) |
Restart time | < 250 ms (Boot time) |
Recovery time | 250 ms (following demand of the safety function) |
General
Nominal operating mode | 100% operating factor |
---|---|
Net weight | 104.382 g |
Mounting position | vertical or horizontal |
Mounting type | DIN rail mounting |
Assembly instructions | See derating curve |
Degree of protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Housing material | PBT |
Housing color | yellow |
Operating voltage display | 1 x green LED |
Status display | 3 x green LED |
Indication | 1 x red LED |
Connection capacity
Connection method | Push-in spring connection |
---|---|
pluggable | Yes |
Conductor cross section solid | 0.2 mm² … 1.5 mm² |
Conductor cross section flexible | 0.2 mm² … 1.5 mm² |
Conductor cross section AWG / kcmil | 24 … 16 |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² … 1.5 mm² (only together with CRIMPFOX 6) |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² … 1.5 mm² (only together with CRIMPFOX 6) |
Stripping length | 8 mm |
Safety-related characteristic data
Stop category | 0 |
---|---|
Designation | IEC 61508 – High demand |
Safety Integrity Level (SIL) | 3 |
Designation | EN ISO 13849 |
Performance level (PL) | e |
Category | 4 |
Designation | EN 62061 |
Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
Designation | Air clearances and creepage distances between the power circuits |
---|---|
Standards/regulations | DIN EN 50178, EN 60947-5-1 |
Rated insulation voltage | 50 V |
50 V AC | |
Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
Degree of pollution | 2 |
Overvoltage category | III |
Shock | 30g |
Vibration (operation) | 10 Hz … 150 Hz, 5g |
Conformance | CE-compliant |
Environmental Product Compliance
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |