Key Commercial Data
| Orderkey | 2904607 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 253 (C-4-2019) |
| GTIN | 4055626255767 |
| Weight per Piece (excluding packing) | 380.000 g |
| Custom tariff number | 85044030 |
| Country of origin | DE (Germany) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C … 70 °C (> 60 °C Derating: 2.5 %/K) |
| Ambient temperature (start-up type tested) | -40 °C |
| Ambient temperature (storage/transport) | -40 °C … 85 °C |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Degree of pollution | 2 |
| Installation height | ≤ 5000 m (> 2000 m, observe derating) |
Input data
| Input voltage range | 100 V AC … 240 V AC -15 % … +10 % |
|---|---|
| 110 V DC … 250 V DC -20 % … +40 % | |
| Dielectric strength maximum | 300 V AC 60 s |
| Frequency range (fN) | 50 Hz … 60 Hz -10 % … +10 % |
| Discharge current to PE | < 0.25 mA (264 V AC, 60 Hz) |
| Current consumption | 1 A (100 V AC) |
| 0.85 A (120 V AC) | |
| 0.46 A (230 V AC) | |
| 0.44 A (240 V AC) | |
| Nominal power consumption | 96.3 VA |
| Inrush current | typ. 11.4 A (at 25 °C) |
| Mains buffering time | typ. 48 ms (120 V AC) |
| typ. 48 ms (230 V AC) | |
| Input fuse | 3.15 A (slow-blow, internal) |
| Recommended breaker for input protection | 6 A … 16 A (Characteristic B, C or comparable) |
| Type of protection | Transient surge protection |
| Protective circuit/component | Varistor |
Output data
| Nominal output voltage | 12 V DC |
|---|---|
| Setting range of the output voltage (USet) | 12 V DC … 15 V DC (constant capacity) |
| Nominal output current (IN) | 7.5 A |
| Dynamic Boost (IDyn.Boost) | 12.75 A (≤ 60 °C (5 s)) |
| Connection in parallel | Yes, for redundancy and increased capacity |
| Connection in series | yes |
| Feedback voltage resistance | ≤ 25 V DC |
| Protection against overvoltage at the output (OVP) | ≤ 18 V DC |
| Control deviation | < 0.3 % (Static load change 10 % … 90 %) |
| < 3 % (Dynamic load change 10 % … 90 %, (10 Hz)) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Residual ripple | < 35 mVPP(with nominal values) |
| Output power | 90 W |
| Typical response time | 300 ms |
| Maximum power dissipation in no-load condition | < 0.6 W (230 V AC) |
| < 0.6 W (120 V AC) | |
| Power loss nominal load max. | < 8.1 W (120 V AC) |
| < 7.1 W (230 V AC) |
General
| Net weight | 0.3 kg |
|---|---|
| Efficiency | typ. 91.5 % (120 V AC) |
| typ. 92.5 % (230 V AC) | |
| Insulation voltage input/output | 4 kV AC (type test) |
| 3 kV AC (routine test) | |
| Protection class | II |
| Degree of protection | IP20 |
| MTBF (IEC 61709, SN 29500) | > 1221000 h (25 °C) |
| > 671000 h (40 °C) | |
| > 248000 h (60 °C) |
Connection data, input
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 10 mm |
Connection data, output
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 10 mm |
Connection data for signaling
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 10 mm |
Standards
| Standard – Safety of transformers | EN 61558-2-16 |
|---|---|
| Standard – safety for equipment for measurement, control, and laboratory use | IEC 61010-1 |
| Standard – Safety extra-low voltage | IEC 61010-1 (SELV) |
| IEC 61010-2-201 (PELV) | |
| Standard – Safe isolation | IEC 61558-2-16 |
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Conformance/approvals
| UL approvals | UL Listed UL 61010-1 |
|---|---|
| UL Listed UL 61010-2-201 | |
| ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
| SIQ | CB-Scheme (IEC 61010-1, IEC 61010-2-201) |
EMC data
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Conducted noise emission | EN 55016 |
| EN 61000-6-3 (Class B) | |
| Noise emission | EN 55016 |
| EN 61000-6-3 (Class B) | |
| Harmonic currents | EN 61000-3-2 |
| EN 61000-3-2 (Class A) | |
| Flicker | EN 61000-3-3 |
| Electrostatic discharge | EN 61000-4-2 |
| Contact discharge | 8 kV (Test Level 4) |
| Discharge in air | 15 kV (Test Level 4) |
| Electromagnetic HF field | EN 61000-4-3 |
| Frequency range | 80 MHz … 1 GHz |
| Test field strength | 20 V/m (Test Level 3) |
| Frequency range | 1 GHz … 6 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Comments | Criterion A |
| Fast transients (burst) | EN 61000-4-4 |
| Input | 4 kV (Test Level 4 – asymmetrical) |
| Output | 4 kV (Test Level 4 – asymmetrical) |
| Signal | 4 kV (Test Level 4 – asymmetrical) |
| Comments | Criterion A |
| Surge voltage load (surge) | EN 61000-4-5 |
| Input | 2 kV (Test Level 4 – symmetrical) |
| 4 kV (Test Level 4 – asymmetrical) | |
| Output | 1 kV (Test Level 3 – symmetrical) |
| 2 kV (Test Level 3 – asymmetrical) | |
| Signal | 0.5 kV (Test Level 2 – symmetrical) |
| Comments | Criterion A |
| I/O/S | asymmetrical |
| Frequency range | 0.15 MHz … 80 MHz |
| Voltage | 10 V (Test Level 3) |
| Comments | Criterion A |
| Frequency | 16.67 Hz |
| 50 Hz | |
| 60 Hz | |
| Test field strength | 100 A/m |
| Additional text | 60 s |
| Comments | Criterion A |
| Frequency | 50 Hz |
| 60 Hz | |
| Test field strength | 1 kA/m |
| Additional text | 3 s |
| Frequency | 0 Hz |
| Test field strength | 300 A/m |
| Additional text | DC, 60 s |
| Voltage dips | EN 61000-4-11 |
| Voltage | 100 V AC |
| Frequency | 60 Hz |
| Voltage dip | 70 % |
| Number of periods | 0.5 / 1 / 30 periods |
| Additional text | Test Level 2 |
| Comments | Criterion A |
| Voltage dip | 40 % |
| Number of periods | 5 / 10 / 50 periods |
| Additional text | Test Level 2 |
| Comments | Criterion B |
| Voltage dip | 0 % |
| Number of periods | 0.5 / 1 / 5 / 50 periods |
| Additional text | Test Level 2 |
| Comments | Criterion B |
| Pulse-shape magnetic field | EN 61000-4-9 |
| Test field strength | 1000 A/m |
| Comments | Criterion A |
| Attenuated sinusoidal oscillations (ring wave) | EN 61000-4-12 |
| Input | 2 kV (symmetrical) |
| 4 kV (asymmetrical) | |
| Comments | Criterion A |
| Asymmetrical conducted disturbance variables | EN 61000-4-16 |
| Test level 1 | 16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) |
| Voltage | 30 V (10 s) |
| Test level 2 | 16.67 Hz 50 Hz 60 Hz (Test Level 2) |
| Voltage | 300 V (1 s) |
| Comments | Criterion A |
| Attenuated oscillating wave | EN 61000-4-18 |
| Voltage | 1 kV (symmetrical) |
| 2.5 kV (asymmetrical) | |
| 1 kV (symmetrical) | |
| Comments | Criterion A |
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
Classifications
[email protected]
| [email protected] 5.1 | 27242213 |
|---|---|
| [email protected] 6.0 | 27049000 |
| [email protected] 7.0 | 27049002 |
| [email protected] 8.0 | 27049002 |
| [email protected] 9.0 | 27040701 |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C … 70 °C (> 60 °C Derating: 2.5 %/K) |
| Ambient temperature (start-up type tested) | -40 °C |
| Ambient temperature (storage/transport) | -40 °C … 85 °C |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Degree of pollution | 2 |
| Installation height | ≤ 5000 m (> 2000 m, observe derating) |