Key Commercial Data
Orderkey | 3260062 |
---|---|
Packing unit | 10 pc |
Minimum order quantity | 10 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 127 (C-1-2017) |
GTIN | 4046356998048 |
Weight per Piece (excluding packing) | 162.530 g |
Custom tariff number | 85369010 |
Country of origin | PL (Poland) |
General
Number of positions | 1 |
---|---|
Number of levels | 1 |
Number of connections | 2 |
Potentials | 1 |
Nominal cross section | 50 mm² |
Color | blue |
Insulating material | PA |
Flammability rating according to UL 94 | V0 |
Rated surge voltage | 8 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | I |
Maximum power dissipation for nominal condition | 4.73 W |
Maximum load current | 150 A (with 50 mm² conductor cross section) |
Nominal current IN | 150 A |
Nominal voltage UN | 1000 V AC |
1500 V DC | |
Open side panel | No |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
Static insulating material application in cold | -60 °C |
Behavior in fire for rail vehicles (DIN 5510-2) | Test passed |
Flame test method (DIN EN 60695-11-10) | V0 |
Oxygen index (DIN EN ISO 4589-2) | >32 % |
NF F16-101, NF F10-102 Class I | 2 |
NF F16-101, NF F10-102 Class F | 2 |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 – HL 3 |
Connection data
Connection method | Power-Turn connection |
---|---|
Connection in acc. with standard | IEC 60947-7-1 |
Conductor cross section solid min. | 10 mm² |
Conductor cross section solid max. | 70 mm² |
Conductor cross section AWG min. | 8 |
Conductor cross section AWG max. | 2/0 |
Conductor cross section flexible min. | 10 mm² |
Conductor cross section flexible max. | 70 mm² |
Min. AWG conductor cross section, flexible | 8 |
Max. AWG conductor cross section, flexible | 2/0 |
Conductor cross section flexible, with ferrule without plastic sleeve min. | 10 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. | 50 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 10 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 50 mm² |
Cross section with insertion bridge solid min. | 10 mm² |
Cross section with insertion bridge, solid max. | 50 mm² |
Cross section with insertion bridge stranded min. | 10 mm² |
Cross section with insertion bridge, stranded max. | 50 mm² |
Cross section with insertion bridge stranded, with ferrule without plastic sleeve min. | 10 mm² |
Cross section with insertion bridge stranded, with ferrule without plastic sleeve max. | 50 mm² |
Cross section with insertion bridge stranded, with ferrule without plastic sleeve min. | 10 mm² |
Cross section with insertion bridge stranded, with ferrule with plastic sleeve max. | 50 mm² |
Stripping length | 30 mm … 32 mm |
Internal cylindrical gage | A10 |
Standards and Regulations
Connection in acc. with standard | IEC 60947-7-1 |
---|---|
Flammability rating according to UL 94 | V0 |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 – HL 3 |
Environmental Product Compliance
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |