Key Commercial Data
Orderkey | 3281176 |
---|---|
Packing unit | 25 pc |
Minimum order quantity | 25 pc |
GTIN | 4055626406893 |
Weight per Piece (excluding packing) | 25.530 g |
Custom tariff number | 85369010 |
Country of origin | IN (India) |
General
Number of levels | 1 |
---|---|
Number of connections | 2 |
Potentials | 1 |
Nominal cross section | 16 mm² |
Color | black |
Insulating material | PC |
Flammability rating according to UL 94 | V0 |
Rated surge voltage | 8 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | IIIa |
Maximum power dissipation for nominal condition | 2.43 W |
Ambient temperature (operation) | -40 °C … 110 °C |
Maximum load current | 76 A |
Nominal current IN | 76 A |
Nominal voltage UN | 690 V |
Open side panel | Yes |
Shock protection test specification | IEC 60529:2001-02 |
Back of the hand protection | guaranteed |
Finger protection | guaranteed |
Result of surge voltage test | Test passed |
Surge voltage test setpoint | 9.8 kV |
Result of power-frequency withstand voltage test | Test passed |
Power frequency withstand voltage setpoint | 1.89 kV |
Result of the test for mechanical stability of terminal points (5 x conductor connection) | Test passed |
Result of tight fit on support | Test passed |
Tight fit on carrier | NS 35 |
Setpoint | 5 N |
Result of voltage-drop test | Test passed |
Requirements, voltage drop | ≤ 3.2 mV |
Result of temperature-rise test | Test passed |
Short circuit stability result | Test passed |
Conductor cross section short circuit testing | 16 mm² |
Short-time current | 1.92 kA |
Result of thermal test | Test passed |
Proof of thermal characteristics (needle flame) effective duration | 30 s |
Connection data
Connection method | Ring cable lug |
---|---|
Connection in acc. with standard | IEC 60947-7-1 |
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 16 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 16 mm² |
Min. AWG conductor cross section, flexible | 20 |
Max. AWG conductor cross section, flexible | 6 |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.5 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 16 mm² |
Cable lug connection according to standard | DIN 46234 |
Min. cross section for cable lug connection | 0.5 mm² |
Max. cross section for cable lug connection | 16 mm² |
AWG min | 20 |
AWG max | 6 |
Hole diameter, min. | 5.1 mm |
Cable lug width, max. | 12.7 mm |
Bolt diameter | 5 mm |
Screw thread | M5 |
Tightening torque, min | 2.6 Nm |
Tightening torque max | 3.7 Nm |
Screw thread | M5 |
Tightening torque, min | 2.6 Nm |
Tightening torque max | 3.7 Nm |
Connection data (JIS standard)
Connection method | Ring cable lug |
---|---|
Connection in acc. with standard | JIS 8207-7-1 |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 14 mm² |
Cable lug connection according to standard | JIS 8207-7-1 |
Min. cross section for cable lug connection | 0.5 mm² |
Max. cross section for cable lug connection | 14 mm² |
Hole diameter, min. | 5.1 mm |
Cable lug width, max. | 12.7 mm |
Bolt diameter | 5 mm |
Screw thread | M5 |
Tightening torque, min | 2.6 Nm |
Tightening torque max | 3.7 Nm |
Nominal current IN | 70 A |
Maximum load current | 70 A |
Nominal voltage UN | 600 V |
Standards and Regulations
Connection in acc. with standard | IEC 60947-7-1 |
---|---|
Flammability rating according to UL 94 | V0 |