Key Commercial Data
Orderkey | 3049958 |
---|---|
Packing unit | 50 pc |
Minimum order quantity | 50 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 377 (C-1-2017) |
GTIN | 4046356431378 |
Weight per Piece (excluding packing) | 25.120 g |
Custom tariff number | 85369010 |
Country of origin | CN (China) |
General
Note | Note: the BE-RT… path extension is to be used for non-insulated cable lugs (see accessories). |
---|---|
Number of levels | 1 |
Number of connections | 2 |
Potentials | 1 |
Nominal cross section | 2.5 mm² |
Color | green-yellow |
Insulating material | PA |
Flammability rating according to UL 94 | V0 |
Rated surge voltage | 8 kV |
Degree of pollution | 3 |
Overvoltage category | III |
Insulating material group | I |
Nominal current IN | 24 A |
Nominal voltage UN | 1000 V |
Open side panel | Yes |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
Static insulating material application in cold | -60 °C |
Dimensions
Width | 12.3 mm |
---|---|
End cover width | 2.2 mm |
Length | 66 mm |
Height NS 35/7,5 | 51 mm |
Height NS 35/15 | 58.5 mm |
Connection data
Note | Please observe the current carrying capacity of the DIN rails. |
---|---|
Connection method | Bolt connection |
Screw thread | M3 |
Tightening torque, min | 0.6 Nm |
Tightening torque max | 0.8 Nm |
Connection in acc. with standard | IEC 60947-7-2 |
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.1 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Min. AWG conductor cross section, flexible | 26 |
Max. AWG conductor cross section, flexible | 14 |
Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.1 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
Cable lug connection according to standard | DIN 46234 |
Min. cross section for cable lug connection | 0.5 mm² |
Max. cross section for cable lug connection | 2.5 mm² |
Hole diameter, min. | 3.2 mm |
Cable lug width, max. | 6 mm |
Bolt diameter | 3 mm |
Cable lug connection according to standard | DIN 46237 |
Min. cross section for cable lug connection | 1 mm² |
Max. cross section for cable lug connection | 2.5 mm² |
Hole diameter, min. | 3.2 mm |
Cable lug width, max. | 6 mm |
Bolt diameter | 3 mm |
Standards and Regulations
Connection in acc. with standard | IEC 60947-7-2 |
---|---|
Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |