Key Commercial Data
Orderkey | 1415429 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 209 (PC-2009) |
GTIN | 4046356474894 |
Weight per Piece (excluding packing) | 113.000 g |
Custom tariff number | 85444210 |
Country of origin | PL (Poland) |
Ambient conditions
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -20 °C … 70 °C (cable, fixed installation) |
-10 °C … 50 °C (cable, flexible installation) |
General data
Number of positions | 8 |
---|---|
Overvoltage category | I |
Degree of pollution | 1 |
Alternative short product description | Ethernet cable |
Cable
Cable type | Ethernet 10 Gbit |
---|---|
Cable type (abbreviation) | 94F |
UL AWM style | 20963 (80°C/30 V) |
Signal type/category | Ethernet CAT6A, 10 Gbps |
Cable structure | 4x2xAWG26/7; S/FTP |
Conductor cross section | 4x 2x 0.14 mm² |
AWG signal line | 26 |
Conductor structure signal line | 7x 0.16 mm |
Core diameter including insulation | 1.04 mm |
Wire colors | white/blue-blue, white/orange-orange, white/green-green, white/brown-brown |
Twisted pairs | 2 cores to the pair |
Type of pair shielding | Aluminum-lined foil |
Overall twist | 4 pairs for core |
Shielding | Tinned copper braided shield |
Optical shield covering | 70 % |
External sheath, color | water blue RAL 5021 |
Outer sheath thickness | 0.65 mm |
External cable diameter D | 6.4 mm ±0.2 mm |
Minimum bending radius, fixed installation | 4 x D |
Minimum bending radius, flexible installation | 8 x D |
Tensile strength GRP | ≤ 100 N |
Cable weight | 42 kg/km |
Outer sheath, material | PUR |
Material conductor insulation | Foamed PE |
Conductor material | Bare Cu litz wires |
Insulation resistance | ≥ 500 MΩ*km |
Loop resistance | ≤ 290.00 Ω/km |
Cable capacity | 47 nF/km |
Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
Near end crosstalk attenuation (NEXT) | 75.3 dB (with 1 MHz) |
66.3 dB (at 4 МHz) | |
61.8 dB (at 8 МHz) | |
60.3 dB (at 10 MHz) | |
57.2 dB (at 16 MHz) | |
55.8 dB (at 20 МHz) | |
54.3 dB (at 25 MHz) | |
52.8 dB (at 31.25 МHz) | |
48.4 dB (at 62.5 МHz) | |
45.3 dB (at 100 MHz) | |
40.8 dB (at 200 MHz) | |
39.3 dB (at 250 MHz) | |
38.1 dB (at 300 MHz) | |
36.3 dB (at 400 MHz) | |
34.8 dB (at 500 MHz) | |
Power-summated near end crosstalk attenuation (PSNEXT) | 72.3 dB (with 1 MHz) |
63.3 dB (at 4 МHz) | |
58.8 dB (at 8 МHz) | |
57.3 dB (at 10 MHz) | |
54.2 dB (at 16 MHz) | |
52.8 dB (at 20 МHz) | |
51.3 dB (at 25 MHz) | |
49.9 dB (at 31.25 МHz) | |
45.4 dB (at 62.5 МHz) | |
42.3 dB (at 100 MHz) | |
37.8 dB (at 200 MHz) | |
36.3 dB (at 250 MHz) | |
35.1 dB (at 300 MHz) | |
33.3 dB (at 400 MHz) | |
31.8 dB (at 500 MHz) | |
Attenuation | 3.1 dB (with 1 MHz) |
5.7 dB (at 4 МHz) | |
8 dB (at 8 МHz) | |
8.9 dB (at 10 MHz) | |
11.2 dB (at 16 MHz) | |
12.6 dB (at 20 МHz) | |
14.1 dB (at 25 MHz) | |
15.8 dB (at 31.25 МHz) | |
22.5 dB (at 62.5 МHz) | |
28.7 dB (at 100 MHz) | |
41.4 dB (at 200 MHz) | |
46.6 dB (at 250 MHz) | |
51.4 dB (at 300 MHz) | |
60.1 dB (at 400 MHz) | |
67.9 dB (at 500 MHz) | |
Return loss (RL) | 20 dB (with 1 MHz) |
23 dB (at 4 МHz) | |
24.5 dB (at 8 МHz) | |
25 dB (at 10 MHz) | |
25 dB (at 16 MHz) | |
25 dB (at 20 МHz) | |
24.2 dB (at 25 MHz) | |
23.3 dB (at 31.25 МHz) | |
20.7 dB (at 62.5 МHz) | |
19 dB (at 100 MHz) | |
16.4 dB (at 200 MHz) | |
15.6 dB (at 250 MHz) | |
15.6 dB (at 300 MHz) | |
15.6 dB (at 400 MHz) | |
15.6 dB (at 500 MHz) | |
Signal runtime | 5.13 ns/m |
Shield attenuation | ≥ 80 dB (at 30 … 100 MHz) |
Nominal voltage, cable | ≤ 100 V |
Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
Test voltage Core/Shield | 700 V (50 Hz, 1 min.) |
Flame resistance | according to IEC 60332-1-2 |
Halogen-free | according to IEC 60754-1 |
Resistance to oil | in accordance with DIN EN 60811-2-1 |
Ambient temperature (operation) | -40 °C … 80 °C (cable, fixed installation) |
-20 °C … 80 °C (cable, flexible installation) | |
Ambient temperature (installation) | -20 °C … 80 °C |
Ambient temperature (storage/transport) | -20 °C … 80 °C |
Environmental Product Compliance