Key Commercial Data
Orderkey | 1402765 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
GTIN | 4046356631389 |
Weight per Piece (excluding packing) | 166.700 g |
Custom tariff number | 85444210 |
Country of origin | PL (Poland) |
Mechanical characteristics
Number of positions | 4 |
---|---|
Shielded | yes |
Insertion/withdrawal cycles | ≥ 100 |
Cable diameter | 7.25 mm |
Cable outlet | straight |
Cable structure | 1x4xAWG22/7; SF/TQ |
No. of cable outlets | 1 |
Line characteristics
Cable type | PROFINET railway applications |
---|---|
Cable structure | 1x4xAWG22/7; SF/TQ |
Conductor cross section | 4x 0.34 mm² |
AWG signal line | 22 |
Conductor structure signal line | 7x 0.25 mm |
Core diameter including insulation | approx. 1.5 mm |
External cable diameter | 6.6 mm ±0.4 mm |
Wire colors | white-blue, orange-yellow |
External sheath, color | black RAL 9005 |
Transmission medium | Copper |
Conductor resistance | ≤ 54.4 Ω/km |
Working capacitance | ≤ 65 pF (core-core) |
≤ 100 pF (core-shield) | |
Wave impedance | 100 Ω ±5 Ω (f = 100 MHz) |
Near end crosstalk attenuation (NEXT) | 73 dB (with 1 MHz) |
70 dB (at 4 МHz) | |
65 dB (at 10 MHz) | |
57 dB (at 31.5 МHz) | |
52 dB (at 62.5 МHz) | |
48 dB (at 100 MHz) | |
Wave attenuation | 2 dB (with 1 MHz) |
4.4 dB (at 4 МHz) | |
7.4 dB (at 10 MHz) | |
14 dB (at 31.5 МHz) | |
20 dB (at 62.5 МHz) | |
26 dB (at 100 MHz) | |
Return Loss | 25 dB (at 4 МHz) |
30 dB (at 10 MHz) | |
30 dB (at 31.5 МHz) | |
30 dB (at 62.5 МHz) | |
28 dB (at 100 MHz) | |
Signal speed | 75 c |
Shield attenuation | 40 dB (30 MHz ≤ f ≤ 100 MHz) |
Coupling resistance | 200.00 mΩ/m (f ≤ 30 MHz) |
Nominal voltage, cable | 300 V AC |
Test voltage, cable | 2000 V AC (50 Hz, 5 minutes) |
Overall twist | Star quad |
Shielding | Plastic-coated aluminum foil, tinned copper braided shield |
Outer sheath, material | PE-X |
Material conductor insulation | Foamed PE |
Conductor material | silver-plated Cu litz wires |
Cable weight | 70 kg/km |
Minimum bending radius, fixed installation | 6 x D |
Flame resistance | EN 60332-1-2 |
EN 50266 | |
EN 60332-3-25 | |
NF C32-070, 2.1 | |
NF C32-070, 2.2 | |
UL 1685, 12 (FT4) | |
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) | |
Halogen-free | According to EN 50267-2-1 |
Resistance to oil | according to IRM 902, 72 h at 100 °C |
Other resistance | Resistance to fuels according to IRM 903, 168 h at 70 °C |
Ambient temperature (operation) | -50 °C … 90 °C (cable, fixed installation) |
-40 °C … 90 °C (cable, flexible installation) |