Technical features
Detection properties
| Nominal sensing distance |
12mm |
|
| Spot dimension |
1,5 x 5mm |
|
| Sensitivity adjustment |
Teach-in |
|
Application
| Function Principle |
Contrast mark detection |
|
| Description |
Standard case – horizontal spot |
|
| Optic position |
axial |
|
| Functions |
Contrast mark detection |
|
Outputs
| Output type |
NPN/PNP – Dark/Light sel., 0-5 V |
|
| Switching frequency |
20kHz |
|
| Response time |
0,025 (20 kHz) |
|
Electrical data
| Operating Voltage |
10…30VDC |
|
| No-Load supply current |
≤ 50mA (≤ 85mA bargraph ON) (≤ 55mA barghapy OFF in normal function) |
|
| Load current |
≤100mA |
|
| Output voltage drop |
≤2V |
|
| Max ripple content |
≤ 2Vpp |
|
| LED indicators |
Yellow (output state) 5 segment bargrapy |
|
| Short-circuit protection |
YES |
|
| Reverse Polarity Protection |
Yes |
|
| Emission |
LED RGB |
|
| Interference to external light |
according to EN 60947-5-2 : 2020 |
|
| Impulsive Overvoltage Protection |
Yes |
|
| Insulation resistance |
>20 MΩ 500 Vdc, between electronics and housing |
|
| Contact resistance |
500 Vac 1 min., between electronics and housing |
|
Mechanical data
| Dimensions |
32x60x82 |
|
| Housing Material |
Metal – Aluminium / Glass |
|
| Connections |
M12 plug |
|
| Active Head Material |
Glass |
|
| Storage temperature |
– 20°C…+70°C |
|
| Material | ||
| Diameter/Dimension |
Cubic |
|
Test/Approvals
| Approvals |
CE cULus |
|
| Shocks and vibrations |
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) |
|
Generical Data
| Dimensions |
32x60x82 |
|
| Operating Temperature |
– 10°C…+ 55°C |
|
| Mechanical Protection |
IP67 |
|