Features
Application Explosive areas Ex-approvals ATEX for gas: II 3G Ex nA op is IIC T4 Gc X
ATEX for dust: II 3D Ex tc IIIC T135°C Dc
System part Receiver Resolution 40 mm Scanning range 7 m Protective field height 1,350 mm Synchronization Optical synchronisation Items supplied Receiver
8 sliding nuts for side mounting
Test rod with diameter corresponding to the resolution of the safety light curtain
Adhesive label with information on the daily check
Operating instructions on CD-ROM
CDS (Configuration & Diagnostic Software)
“Notes for explosion protection” label(s)
-
Safety-related parameters
Type Type 4 (IEC 61496-1) Safety integrity level SIL3 (IEC 61508) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHD (mean probability of a dangerous failure per hour) 15 * 10-9 TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state.
-
Functions
Functions Delivery status Protective operation ✔ Restart interlock ✔ Internal External device monitoring (EDM) ✔ Deactivated Beam coding ✔ Code 1 Configurable scanning range ✔ 0.5 m … 7 m Reduced resolution ✔ 2 beams Self-teaching dynamic blanking for goods detection ✔ Multiple sampling ✔ 2x evaluation Direction monitoring ✔ Object entry monitoring ✔ Safe SICK device communication via EFI ✔
-
Interfaces
System connection Hirschmann male connector M26, 12-pin Direction of cable connection Straight Conductor cross section 0.75 mm² Permitted cable length ≤ 50 m Configuration connection Female connector M8, 4-pin Configuration method PC with CDS (Configuration and Diagnostic Software) Display elements 7-segment display
-
Electrical data
Protection class III (IEC 61140) Supply voltage VS 24 V DC (19.2 V … 28.8 V) 1) Residual ripple ≤ 10 % 2) Output signal switching devices (OSSDs) Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3) ON state, switching voltage HIGH 24 V DC (VS – 2.25 V DC … VS) OFF state, switching voltage LOW ≤ 2 V DC Current-carrying capacity per OSSD ≤ 500 mA - 1) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as accessories from SICK.
- 2) Within the limits of VS.
- 3) Applies to the voltage range between –30 V and +30 V.
-
Mechanical data
Dimensions See dimensional drawing Housing cross-section 40 mm x 48 mm Housing material Aluminum extruded profile Weight 2,850 g
-
Ambient data
Enclosure rating IP65 (EN 60529) Ambient operating temperature 0 °C … +55 °C Storage temperature –25 °C … +70 °C Air humidity 15 % … 95 %, Non-condensing Vibration resistance 5 g, 10 Hz … 55 Hz (EN 60068-2-6) Shock resistance 10 g, 16 ms (EN 60068-2-27)
-
Classifications
eCl@ss 5.0 27272704 eCl@ss 5.1.4 27272704 eCl@ss 6.0 27272704 eCl@ss 6.2 27272704 eCl@ss 7.0 27272704 eCl@ss 8.0 27272704 eCl@ss 8.1 27272704 eCl@ss 9.0 27272704 eCl@ss 10.0 27272704 eCl@ss 11.0 27272704 eCl@ss 12.0 27272704 ETIM 5.0 EC002549 ETIM 6.0 EC002549 ETIM 7.0 EC002549 ETIM 8.0 EC002549 UNSPSC 16.0901 46171620