-
Features
Application Machines with strong shock or vibration loads System part Sender Resolution 30 mm Scanning range 6 m Protective field height 1,200 mm No blind zones Yes Synchronization Optical synchronisation Items supplied Sender
-
Safety-related parameters
Type Type 2 (IEC 61496-1) Safety integrity level SIL1 (IEC 61508) Category Category 2 (ISO 13849-1) Performance level PL c (ISO 13849-1) PFHD (mean probability of a dangerous failure per hour) 31.0 x 10-9 TM (mission time) 20 years (ISO 13849-1) Safe state in the event of a fault At least one OSSD is in the OFF state.
-
Functions
Protective operation ✔
-
Interfaces
System connection Male connector M12, 5-pin Length of cable 150 mm Cable diameter 4.3 mm Cable bend radius Stationary position > 12 x cable diameter Flexible use > 15 x cable diameter Display elements LEDs
-
Electrical data
Protection class III (IEC 61140) Supply voltage VS 24 V DC (19.2 V … 28.8 V) Ripple ≤ 10 % Power consumption typical 1.1 W (DC)
-
Mechanical data
Dimensions See dimensional drawing Housing material Aluminum extruded profile
-
Ambient data
Enclosure rating IP65 (IEC 60529)
IP67 (IEC 60529)
Ambient operating temperature –30 °C … +55 °C Storage temperature –30 °C … +70 °C Air humidity 15 % … 95 %, Non-condensing Vibration resistance 20 g, 10 Hz … 200 Hz (In each axis)
15 g, 200 Hz … 400 Hz (In each axis)
Shock resistance 10 g, 16 ms (IEC 60068-2-27)
-
Other information
Wave length 850 nm Type of light Near-infrared (NIR), invisible
-
Classifications
eCl@ss 5.0 27272704 eCl@ss 5.1.4 27272704 eCl@ss 6.0 27272704 eCl@ss 6.2 27272704 eCl@ss 7.0 27272704 eCl@ss 8.0 27272704 eCl@ss 8.1 27272704 eCl@ss 9.0 27272704 eCl@ss 10.0 27272704 eCl@ss 11.0 27272704 eCl@ss 12.0 27272704 ETIM 5.0 EC002549 ETIM 6.0 EC002549 ETIM 7.0 EC002549 ETIM 8.0 EC002549 UNSPSC 16.0901 46171620