Features
Functional principle Sender/receiver Sensing range Limit values 70 mm … 2,150 mm Parallel beam (recommended) 70 mm … 1,500 mm 9 x cross beam (recommended) 630 mm … 1,500 mm Blind zone Distance from 1st Beam to leading edge of housing (connection side) 4.6 mm Distance from last beam to leading edge of housing (top) 19.6 mm 1) Detection height 500 mm Beam separation 25 mm Optical light exit Slim Detection capability Minimum detectable object (MDO), parallel beam 30 mm 2) Minimum detectable object (MDO), 9 x cross beam ≥ 11.5 mm 2) Minimum object width (MOW), 9 x cross beam 21 % 3) 4) Factory setting Beam function 9 x cross beam Pin 2 (MF) Teach-in input Pin 4 (OUT) Object detection output = “HIGH” IO-Link (process data) QL/Qint Status, System status, Beam status Teach-in (default) Auto teach-in Adjustment IO-Link For configuring the sensor parameters and Smart Task functions Emitted beam Light source LED Type of light Infrared light Number of beams 20 LED key figures Normative reference EN 62471:2008-09 | IEC 62471:2006, modified LED risk group marking Free group Wave length 850 nm Average service life Average service life: 100,000 h at TU = +25 °C Time specifications Initialization time 0.4 s … 2 s 5) Teach-in time 0.75 s … 50 s 5) Scan time, parallel beam 1.6 ms Scan time, cross beam 3.1 ms Repeatability, parallel beam 1.6 ms Repeatability, cross beam 4.7 ms Minimum dwell time, parallel beam 3.1 ms Minimum dwell time, cross beam 6.3 ms Max. response time, parallel beam 4.8 ms Max. response time, cross beam 9.4 ms Type of synchronization Optical (2 beams) - 1) For a detection height < 700 mm, the measured value can vary by up to 1 mm from the measured values specified here.
- 2) MDO: Minimum detectable size of an arbitrarily shaped object.
- 3) MOW: Minimum detectable width of an arbitrarily thin object.
- 4) % value relates to the installed distance between the sender and receiver.
- 5) Depends on the sensing range / number of beams / cross beam.
-
Communication interface
IO-Link ✔ , V1.1 Data transmission rate COM3 (230,4 kBaud) Maximum cable length 20 m Cycle time 2.3 ms Process data length 32 Byte
-
Electrical data
Supply voltage UB DC 18 V DC … 30 V DC 1) Ripple ≤ 1.3 Vpp Power consumption Sender ≤ 36.5 mA 2) Receiver ≤ 51 mA 2) Digital output Number 2 Type Push-pull: PNP/NPN Output signal voltage HIGH/LOW UB-3 V/<3 V Output load, Inductive 1 H Output load, capacitive 100 nF Output current Imax. 100 mA Output current, rest < 0.5 mA Digital input Number 1 Input signal voltage HIGH/LOW >15 V/<5 V Protection class III 3) UL File No. NRKH.E181493 & NRKH7.E181493 Circuit protection UV connections, reverse polarity protected
Output Q short-circuit protected
Outputs overcurrent and short-circuit protected
- 1) Without load.
- 2) At 24 V.
- 3) EN 61140.
-
Mechanical data
Dimensions (W x H x D) Width 11.8 mm Height 499.2 mm Depth 24.1 mm Connection type Cable with M12 male connector, 4-pin Connection type Detail Cable diameter 3.4 mm Conductor cross section 0.14 mm² Length of cable 150 mm Cable material PVC Material Housing Aluminum Plastic Front screen PMMA Weight 1,060 g Overvoltage protection (required) 1
-
Ambient data
Enclosure rating IP65 1)
IP67
Ambient temperature, operation –25 °C … +55 °C Ambient temperature, storage –25 °C … +70 °C Ambient light immunity Indirect: 50,000 lx 2) Shock resistance 10 g, 16 ms, DIN EN 60068-2-27 Vibration resistance 10-150 Hz 0.5 mm, IEC 60068-2-6 Air humidity ≤ 96 %, Relative humidity (no condensation) Electromagnetic compatibility (EMC) EN 61000-6-2, EN 61000-6-4 - 1) Operating in outdoor condition only with a external protection housing.
- 2) Sunlight.
-
Smart Task
Smart Task name Base logics Logic function Direct
AND
OR
Timer function Deactivated
On delay
Off delay
ON and OFF delay
Impulse (one shot)
Switching signal Switching signal QL1 Switching output Switching signal QL2 Switching output, external input
-
Diagnosis
Diagnostics functions Device state Hardware error, temperature warning, operating hours warning Communication state Pin short-circuit error, invalid process data Status of the light signal Teach error, synchronization error, quality-of-run alarm Alarm output Yes
-
Classifications
eCl@ss 5.0 27270910 eCl@ss 5.1.4 27270910 eCl@ss 6.0 27270910 eCl@ss 6.2 27270910 eCl@ss 7.0 27270910 eCl@ss 8.0 27270910 eCl@ss 8.1 27270910 eCl@ss 9.0 27270910 eCl@ss 10.0 27270910 eCl@ss 11.0 27270910 eCl@ss 12.0 27270910 ETIM 5.0 EC002549 ETIM 6.0 EC002549 ETIM 7.0 EC002549 ETIM 8.0 EC002549 UNSPSC 16.0901 39121528