Features
Application Outdoor Light source Infrared (886 nm) Laser class 1, complies with 21 CFR 1040.10 except for the conformance according to “Laser Notice No. 56” from May 8, 2019 (IEC 60825-1:2014, EN 60825-1:2014) Aperture angle Horizontal 360° Scanning frequency 12.5 Hz
25 Hz
Angular resolution 0.02°
0.04°
0.06°
0.08°
0.1°
0.12°
0.2°
0.24°
Heating Self-heating Working range 0.2 m … 130 m Scanning range At 10% remission 40 m At 90% remission 130 m Spot size 2.6 mrad x 0.4 mrad (Single spot)
2.6 mrad x 0.4 mrad (+ angular resolution for HDDM+)
Amount of evaluated echoes 3
-
Mechanics/electronics
Connection type 3 x M12 Supply voltage 10 V DC … 30 V DC Power consumption Typ. 13 W, Max. 20 W Output current ≤ 0.25 A Housing AlSi12 Housing color Gray (RAL 7042) Optical hood Polycarbonat (PC) Enclosure rating IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013)
IP67 (IEC 60529:1989+AMD1:1999+AMD2:2013)
Protection class III (IEC 61140:2016-11) Electrical safety IEC 61010-1:2010-06 Weight 1.7 kg Dimensions (L x W x H) 151.9 mm x 150 mm x 126.7 mm
-
Performance
Scan/frame rate 37,500 measurement point/s … 225,000 measurement point/s Response time ≥ 40 ms Detectable object shape Almost any Systematic error ± 15 mm Statistical error < 10 mm Temperature drift ± 0.2 mm/K Filter Median filter
Average filter
-
Interfaces
Ethernet ✔ , TCP/IP, UDP/IP Function Host Data transmission rate 10/100 MBit/s Digital inputs 6 Encoder inputs 2 Digital outputs 6 Optical indicators LEDs Configuration software Web server
-
Ambient data
Object remission 2 % … 1,000 % (Reflector) Electromagnetic compatibility (EMC) Emitted radiation Residential area (EN 61000-6-3:2007+AMD:A1:2011) Electromagnetic immunity Industrial environment (EN 61000-6-2:2005) Vibration resistance Sine test 10 Hz … 500 Hz, 5 g, 10 frequency cycles 1) Shock resistance 50 g, 11 ms, 6 shocks per axis 2)
25 g, 6 ms, 1000 shocks per axis 2)
Ambient operating temperature –30 °C … +50 °C Storage temperature –40 °C … +75 °C Permissible relative humidity ≤ 90 %, Non-condensing Ambient light immunity 80 klx - 1) EN 60068-2-6:2007.
- 2) EN 60068-2-27:2008.
-
General notes
Note on use The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
-
Classifications
eCl@ss 5.0 27270990 eCl@ss 5.1.4 27270990 eCl@ss 6.0 27270913 eCl@ss 6.2 27270913 eCl@ss 7.0 27270913 eCl@ss 8.0 27270913 eCl@ss 8.1 27270913 eCl@ss 9.0 27270913 eCl@ss 10.0 27270913 eCl@ss 11.0 27270913 eCl@ss 12.0 27270913 ETIM 5.0 EC002550 ETIM 6.0 EC002550 ETIM 7.0 EC002550 ETIM 8.0 EC002550 UNSPSC 16.0901 41111615