Features
Functional principle Photoelectric retro-reflective sensor Functional principle detail Dual lens Dimensions (W x H x D) 20 mm x 60 mm x 43.9 mm Housing design (light emission) Rectangular Sensing range max. 0.01 m … 15 m 1)
0.01 m … 12 m 2)
Sensing range 0.01 m … 13 m 1)
0.01 m … 11 m 2)
Focus Approx. 2° Type of light Visible red light Light source LED 3) Light spot size (distance) Ø 260 mm (8 m) Angle of dispersion Approx. 2° Adjustment Potentiometer, 2 turns 4) - 1) Reflector PL80A.
- 2) Reflector P250.
- 3) Average service life: 100,000 h at TU = +25 °C.
- 4) With position indicator.
-
Mechanics/electronics
Supply voltage 24 V DC … 240 V DC 1)
24 V AC/DC … 240 V AC/DC 1)
Power consumption ≤ 5 VA Switching output Relay, electrically isolated 2) Output function Change-over contacts Switching mode Light switching 2) Switching current (switching voltage) 3 A (240 V AC)
3 A (30 V DC)
Response time ≤ 15 ms Switching frequency 33 Hz 3) Connection type Cable, 5-wire, 5 m 4) Cable material PVC Conductor cross section 0.76 mm² Cable diameter Ø 6.4 mm Circuit protection A 5)
C 6)
Protection class II 7) Overvoltage category 2 Weight 330 g Polarisation filter ✔ Housing material Plastic, ABS Optics material Plastic, PMMA Enclosure rating IP67 Items supplied Reflector P250, BEF-W250 mounting bracket Electromagnetic compatibility (EMC) EN 60947-5-2 8) Ambient operating temperature –25 °C … +55 °C Ambient temperature, storage –40 °C … +70 °C UL File No. NRKH2.E300503 & NRKH8.E300503 - 1) +- 10%.
- 2) Provide suitable spark suppression for inductive or capacitive loads.
- 3) With light/dark ratio 1:1.
- 4) Do not bend below 0 °C.
- 5) A = VS connections reverse-polarity protected.
- 6) C = interference suppression.
- 7) Reference voltage: 250 V AC.
- 8) The AC/DC devices comply with the Radio Safety Requirements for the industrial sector (Radio Safety Class A). They may cause radio interference if used in a residential area.
-
Safety-related parameters
MTTFD 1,541 years DCavg 0 % B10d 68,000 Switching cycles 1) - 1) Only for devices containing electro-mechanical components. In this case, the MTTFD value of the entire device must be calculated from the given B10D value, the number of switching cycles and the given MTTFD value.
-
Classifications
eCl@ss 5.0 27270902 eCl@ss 5.1.4 27270902 eCl@ss 6.0 27270902 eCl@ss 6.2 27270902 eCl@ss 7.0 27270902 eCl@ss 8.0 27270902 eCl@ss 8.1 27270902 eCl@ss 9.0 27270902 eCl@ss 10.0 27270902 eCl@ss 11.0 27270902 eCl@ss 12.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 ETIM 8.0 EC002717 UNSPSC 16.0901 39121528