Features
Functional principle Photoelectric proximity sensor Functional principle detail Background suppression Sensing range max. 20 mm … 350 mm 1) Sensing range 20 mm … 350 mm 1) Emitted beam Light source PinPoint LED 2) Type of light Visible red light Light spot size (distance) Ø 6 mm (200 mm) Key LED figures Wave length 640 nm Adjustment IO-Link
Single teach-in button
Pin 2 configuration External input, Teach-in input, Sender off input, Detection output, logic output - 1) Object with 90% remission (based on standard white, DIN 5033).
- 2) Average service life: 50,000 h at TU = +25 °C.
-
Safety-related parameters
MTTFD 634 years DCavg 0 % TM (mission time) 20 years
-
Communication interface
Communication interface IO-Link V1.1 Communication Interface detail COM2 (38,4 kBaud) Cycle time 2.3 ms Process data length 16 Bit Process data structure Bit 0 = switching signal QL1
Bit 1 = switching signal QL2
Bit 2 … 15 = measuring value
VendorID 26 DeviceID HEX 0x8000EC DeviceID DEC 8388844
-
Electrical data
Supply voltage UB 10 V DC … 30 V DC 1) Ripple < 5 Vpp 2) Current consumption 45 mA 3) Protection class III Digital output Type PNP Signal voltage PNP HIGH/LOW > Uv – 2,5 V / ca. 0 V Output current Imax. ≤ 100 mA Repeatability (response time) 100 µs 4) Switching frequency 1,500 Hz Switching mode Light/dark switching Circuit protection A 5)
B 6)
C 7)
D 8)
Response time Q/ on Pin 2 200 µs … 300 µs 4) 9) Switching frequency Q / to pin 2 ≤ 1,500 Hz 10) - 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Valid for Q on Pin2, if configured with software.
- 5) A = VS connections reverse-polarity protected.
- 6) B = inputs and output reverse-polarity protected.
- 7) C = interference suppression.
- 8) D = outputs overcurrent and short-circuit protected.
- 9) Signal transit time with resistive load.
- 10) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
-
Mechanical data
Housing Rectangular Dimensions (W x H x D) 15.6 mm x 48.5 mm x 42 mm Connection Male connector M12, 4-pin Material Housing Metal, zinc diecast Front screen Plastic, PMMA Weight 120 g
-
Ambient data
Enclosure rating IP66
IP67
Ambient operating temperature –40 °C … +60 °C Ambient temperature, storage –40 °C … +75 °C UL File No. NRKH.E181493 & NRKH7.E181493
-
Smart Task
Smart Task name Counter + debouncing Logic function Direct
WINDOW
Hysteresis
Timer function Deactivated
On delay
Off delay
ON and OFF delay
Impulse (one shot)
Inverter Yes Maximum counting frequency SIO Direct: — 1)
SIO Logic: 1000 Hz 2)
IOL: 650 Hz 3)
Counter reset SIO Direct: —
SIO Logic: 1,5 ms
IOL: 1,5 ms
Min. Time between two process events (switches) SIO Direct: —
SIO Logic: 500 µs
IOL: 800 µs
Debounce time max. SIO Direct: —
SIO Logic: 30.000 ms
IOL: 30.000 ms
Switching signal Switching signal QL1 Output type (dependant on the adjusted threshold) Switching signal QL2 Output type (dependant on the adjusted threshold) Measuring value Counting value - 1) SIO Direct: sensor operation in standard I/O mode without IO-Link communication and without using internal sensor logic or time parameters (set to “direct”/”deactivated”).
- 2) SIO Logic: Sensor operation in standard I/O mode without IO-Link communication. Sensor-internal logic or timing parameters plus Automation Functions used.
- 3) IOL: Sensor operation with full IO-Link communication and usage of logic, timing and Automation Function parameters.
-
Diagnosis
Device status Yes
-
Classifications
eCl@ss 5.0 27270904 eCl@ss 5.1.4 27270904 eCl@ss 6.0 27270904 eCl@ss 6.2 27270904 eCl@ss 7.0 27270904 eCl@ss 8.0 27270904 eCl@ss 8.1 27270904 eCl@ss 9.0 27270904 eCl@ss 10.0 27270904 eCl@ss 11.0 27270904 eCl@ss 12.0 27270903 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 ETIM 8.0 EC002719 UNSPSC 16.0901 39121528