Features
Actuator Pneumatic, valve on board Max. number of sensors Approx. 30 1)
Approx. 50 2)
Logical principle of operation Single accumulation Type of Release Single release, block (slug) release Dimensions (W x H x D) 31 mm x 105 mm x 74 mm Adjustment None Special applications ZoneControl - 1) When powerd from the end of the IR daisy chain.
- 2) When powerd from center of the IR daisy chain.
-
Mechanics/electronics
Supply voltage ≥ 21.6 V DC 1) Ripple < 5 Vpp 2) Current consumption 60 mA 3) Switching output PNP Signal voltage PNP HIGH/LOW Approx. VS – 0.5 V / 0 V Output current Imax. ≤ 100 mA Connection type Cable with female connector, M8, 4-pin, 1.1 m 4) Connection type for daisy chain Cable with M12 male connector, 4-pin 0.5 m Cable material PVC Circuit protection A 5)
C 6)
D 7)
Protection class III Housing material Plastic, ABS Enclosure rating IP40 Ambient operating temperature –10 °C … +55 °C Ambient temperature, storage –25 °C … +75 °C Medium for valves Compressed air or neutral gases filtered, non-lubricated or lubricated Design solenoid valve 3/2-way valve 8) Mode of operation solenoid valve Air to Drive (NC) Connection type solenoid valve Compressed air 2 x 8 mm diameter, output line 4 mm diameter Coil ratings 24 V DC 1 W Air flow rate Approx. 20 Nl/min 9) Ventilation capacity Approx. 130 Nl/min Operating pressure range 2 bar … 8 bar 10) - 1) Limit values, the device may connect only to protected extra low voltage.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load and valve deenergized.
- 4) Do not bend below 0 °C.
- 5) A = VS connections reverse-polarity protected.
- 6) C = interference suppression.
- 7) D = outputs overcurrent and short-circuit protected.
- 8) Other valve types available on request.
- 9) P – A.
- 10) In combination with cylinders with small air volume we recommend tests.
-
Pneumatic
Coil ratings 24 V DC 1 W Medium for valves Compressed air or neutral gases filtered, non-lubricated or lubricated Design solenoid valve 3/2-way valve 1) Connection type solenoid valve Compressed air 2 x 8 mm diameter, output line 4 mm diameter Air flow rate Approx. 20 Nl/min 2) Ventilation capacity Approx. 130 Nl/min Operating pressure range 2 bar … 8 bar 3) - 1) Other valve types available on request.
- 2) P – A.
- 3) In combination with cylinders with small air volume we recommend tests.
-
Classifications
eCl@ss 5.0 27270902 eCl@ss 5.1.4 27270902 eCl@ss 6.0 27270902 eCl@ss 6.2 27270902 eCl@ss 7.0 27270902 eCl@ss 8.0 27270902 eCl@ss 8.1 27270902 eCl@ss 9.0 27270902 eCl@ss 10.0 27270902 eCl@ss 11.0 27270902 eCl@ss 12.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 ETIM 8.0 EC002717 UNSPSC 16.0901 39121528