Number of steps per revolution (max. resolution) 262,144 (18 bit) Number of revolutions 4,096 (12 bit) Max. resolution (number of steps per revolution x number of revolutions) 18 bit x 12 bit (262,144 x 4,096) Error limits G 0.03° 1) Repeatability standard deviation σr 0.002° 2) - 1) In accordance with DIN ISO 1319-1, position of the upper and lower error limit depends on the installation situation, specified value refers to a symmetrical position, i.e. deviation in upper and lower direction is the same.
- 2) In accordance with DIN ISO 55350-13; 68.3% of the measured values are inside the specified area.
-
Interfaces
Communication interface SSI Initialization time 50 ms 1) Position forming time < 1 µs Code type Gray Code sequence parameter adjustable CW/CCW (V/R̅) parameter adjustable Clock frequency ≤ 2 MHz 2) Set (electronic adjustment) H-active (L = 0 – 3 V, H = 4,0 – Us V) CW/CCW (counting sequence when turning) L-active (L = 0 – 1,5 V, H = 2,0 – Us V) - 1) Valid positional data can be read once this time has elapsed.
- 2) Minimum, LOW level (Clock +): 250 ns.
-
Electrical data
Connection type Cable, 8-wire, universal, 1.5 m 1) Supply voltage 4.5 … 32 V Power consumption ≤ 0.7 W (without load) Reverse polarity protection ✔ MTTFd: mean time to dangerous failure 250 years (EN ISO 13849-1) 2) - 1) The universal cable connection is positioned so that it is possible to lay it without bends in a radial or axial direction.
- 2) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
-
Mechanical data
Mechanical design Blind hollow shaft Shaft diameter 3/8″ Weight 0.2 kg 1) Shaft material Stainless steel Flange material Aluminum Housing material Aluminum die cast Start up torque < 0.8 Ncm (+20 °C) Operating torque < 0.6 Ncm (+20 °C) Permissible movement static ± 0.5 mm (axial)
± 0.3 mm (radial)
Permissible movement dynamic ± 0.1 mm (axial)
± 0.05 mm (radial)
Operating speed ≤ 6,000 min⁻¹ 2) Moment of inertia of the rotor 40 gcm² Bearing lifetime 3.0 x 10^9 revolutions Angular acceleration ≤ 500,000 rad/s² - 1) Based on devices with male connector.
- 2) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.
-
Ambient data
EMC According to EN 61000-6-2 and EN 61000-6-3 1) Enclosure rating IP65, shaft side (IEC 60529)
IP67, housing side (IEC 60529) 2)
Permissible relative humidity 90 % (Condensation not permitted) Operating temperature range –40 °C … +100 °C 3) Storage temperature range –40 °C … +100 °C, without package Resistance to shocks 60 g, 6 ms (EN 60068-2-27) Resistance to vibration 20 g, 10 Hz … 2,000 Hz (EN 60068-2-6) - 1) EMC according to the standards quoted is achieved if shielded cables are used.
- 2) For devices with male connector: with mounted mating connector.
- 3) Stationary position of the cable.
-
Classifications
eCl@ss 5.0 27270502 eCl@ss 5.1.4 27270502 eCl@ss 6.0 27270590 eCl@ss 6.2 27270590 eCl@ss 7.0 27270502 eCl@ss 8.0 27270502 eCl@ss 8.1 27270502 eCl@ss 9.0 27270502 eCl@ss 10.0 27270502 eCl@ss 11.0 27270502 eCl@ss 12.0 27270502 ETIM 5.0 EC001486 ETIM 6.0 EC001486 ETIM 7.0 EC001486 ETIM 8.0 EC001486 UNSPSC 16.0901 41112113