Performance
Measuring step 360° /number of steps Measuring step deviation 0.005°, 0.016° Error limits G 0.035° (binary number of steps) 1)
0.046° (non-binary number of steps) 1)
Repeatability standard deviation σr 0.005° 2) - 1) In accordance with DIN ISO 1319-1, position of the upper and lower error limit depends on the installation situation, specified value refers to a symmetrical position, i.e. deviation in upper and lower direction is the same.
- 2) In accordance with DIN ISO 55350-13; 68.3% of the measured values are inside the specified area.
-
Interfaces
Communication interface Parallel data world Initialization time 80 ms 1) Code type Gray Code sequence parameter adjustable CW (clockwise) increasing when viewing the clockwise rotating shaft Measured value backlash 0.005° Response threshold 0.003° - 1) Valid positional data can be read once this time has elapsed.
-
Electrical data
Connection type Male connector, M23, 21-pin, radial Supply voltage 10 … 32 V MTTFd: mean time to dangerous failure 300 years (EN ISO 13849-1) 1) Switching level of control inputs Logic H = 0.7 x US, Logic L = 0 V … 0.3 x US Actuation of set button ≥ 100 ms 2) - 1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
- 2) Only with shaft stationary (note initialisation time).
-
Mechanical data
Mechanical design Blind hollow shaft Shaft diameter 15 mm 1) Weight Approx. 0.3 kg 2) Housing material Aluminum die cast Start up torque Typ. 0.6 Ncm Operating torque Typ. 0.4 Ncm Permissible movement static ± 0.3 mm (radial)
± 0.5 mm (axial)
Permissible movement dynamic ± 0.1 mm (radial)
± 0.2 mm (axial)
Operating speed ≤ 3,000 min⁻¹ Moment of inertia of the rotor See figure Bearing lifetime 3.6 x 109 revolutions Angular acceleration ≤ 500,000 rad/s² - 1) Order collets for 6, 8, 10, and 12 mm and 1/4″, 3/8″, and 1/2″ separately as accessories.
- 2) Based on devices with male connector.
-
Ambient data
EMC According to EN 61000-6-2 and EN 61000-6-3 1) Enclosure rating IP65, male connector (IEC 60529) 2)
IP66, cable (IEC 60529)
Permissible relative humidity 90 % (Condensation not permitted) Operating temperature range –20 °C … +85 °C Storage temperature range –40 °C … +100 °C, without package Resistance to shocks 50 g, 11 ms (EN 60068-2-27) Resistance to vibration 20 g, 10 Hz … 2,000 Hz (EN 60068-2-6) - 1) EMC according to the standards quoted is achieved if shielded cables are used.
- 2) With mating connector fitted.
-
Classifications
eCl@ss 5.0 27270502 eCl@ss 5.1.4 27270502 eCl@ss 6.0 27270590 eCl@ss 6.2 27270590 eCl@ss 7.0 27270502 eCl@ss 8.0 27270502 eCl@ss 8.1 27270502 eCl@ss 9.0 27270502 eCl@ss 10.0 27270502 eCl@ss 11.0 27270502 eCl@ss 12.0 27270502 ETIM 5.0 EC001486 ETIM 6.0 EC001486 ETIM 7.0 EC001486 ETIM 8.0 EC001486 UNSPSC 16.0901 41112113